| Plan Review Notes For Permit 23030433 |
| Permit Number |
23030433 |
|
| Review Stop |
G |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2023-03-08 16:00:23 | 1ST REVIEW FBC-2020 RES. GAS | | | PERMIT- 23030433 | | | 3/8/2023 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) THE GAS RISER DOES NOT SHOW THE GAS PIPING TO THE | | | DRYER AND THE POOL HEATER. THE GAS DRYER IS SHOWN ON | | | THE APPROVED PLANS FOR PERMIT 21070438 (MASTER- | | | 21021363), AND THE GAS POOL HEATER IS SHOWN ON THE | | | APPROVED PLANS FOR THE POOL- 22071358. A COMPLETE RISER | | | IS REQUIRED PER SEC. G2412.3 & G2412.4 FBC RES. | | | | | | 2) THE APPROVED MASTER PLANS UNDER 21021363 SHOW | | | ADEQUATE INDOOR COMBUSTION AIR FOR THE RANGE HOWEVER | | | COMBUSTION AIR CALCULATIONS FOR THE DRYER ARE REQUIRED | | | PER SECS. G2407.1 & G2439.1 FBC RES. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | |
|