| Date |
Text |
| 2023-07-05 16:39:44 | PLAN |
| | REVIEW COMMENTS |
| | |
| | 1ST REVIEW: FBC SEVENTH EDITION (2020) |
| | ROBERT MCDOUGAL, CBO |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | (561) 805-6714 |
| | [email protected] |
| | |
| | DENIED BY BUILDING |
| | PLEASE ADDRESS THE ITEMS NOTED BELOW: |
| | |
| | 1) SUBMIT A COVER SHEET WITH A COMPLETE INDEX OF ALL OF |
| | THE PLAN SHEETS. FBC 107.2.1 |
| | |
| | 2) SUBMIT A LIFE SAFETY PLAN. FBC 107.2.1 |
| | THE LIFE SAFETY PLANS NEED TO SHOW THE FOLLOWING: |
| | A) NUMBER OF OCCUPANTS IN EACH AREA FBC 1004.1 |
| | B) CUMULATIVE OCCUPANT LOADS FBC 1004.1.1 |
| | C) EXIT SEPARATION DISTANCE FBC 1015.2.1 |
| | D) COMMON PATH OF EGRESS TRAVEL DISTANCE FBC 1014.3 |
| | E) EXIT ACCESS TRAVEL DISTANCE FBC 1016.3 |
| | F) CLEAR WIDTH OF THE EXIT OR EXIT ACCESS DOORS FBC |
| | 1008.1.1 |
| | G) CAPACITY OF EGRESS DOORS, OCCUPANT LOAD SERVED AND |
| | MEANS OF EGRESS FACTOR FBC1005.3.2 |
| | H) DISTRIBUTION OF EGRESS CAPACITY FBC1005.5 |
| | |
| | 3) THERE IS A COUPLE OF DISCREPANCIES BETWEEN PLAN |
| | SHEETS S-0.0 AND AG-101. SHEET S-0.0 SPECIFIES THIS AS |
| | A LEVEL 2 ALTERATION AND TYPE V-B CONSTRUCTION. AG-101 |
| | SPECIFIES IT AS A LEVEL 3 ALTERATION AND TYPE II-B |
| | CONSTRUCTION. THIS WORK IS A LEVEL 3 ALTERATION BECAUSE |
| | THERE IS WORK BEING DONE IN THE ENTIRE BUILDING. AS FAR |
| | AS TYPE OF CONSTRUCTION THE MINIMUM TYPE OF |
| | CONSTRUCTION THAT ALLOWS THE HEIGHT, NUMBER OF STORIES |
| | AND AREA FOR THE OCCUPANCY IS USUALLY SPECIFIED. SEE |
| | THE TABLES IN CHAPTERS 5 AND 6. |
| | |
| | 4) ON SHEET S-1.0 THE EXPOSURE CATEGORY IS SPECIFIED AS |
| | C. THIS BUILDING IS ACTUALLY LOCATED IN EXPOSURE |
| | CATEGORY D DUE TO BEING ADJACENT TO A LAKE WITH 5,000 |
| | FT. OF WATER SURFACE. PLEASE ADJUST THE COMPONENT AND |
| | CLADDING PRESSURES ON SHEET S-5.0 FBC 1609.4 |
| | |
| | 5) ASTM C926 REQUIRES 3 COATS OF CEMENT PLASTER |
| | (STUCCO) ON WIRE LATH OVER PLYWOOD (SOLID BASE) WITH A |
| | MINIMUM THICKNESS OF 7/8". ON SHEET A-132, 5/8" STUCCO |
| | IS SPECIFIED. PLEASE CORRECT. FBC 2510.3 |
| | |
| | 6) SUBMIT PRODUCT APPROVALS FOR THE ROOFING MATERIALS, |
| | WINDOWS AND EXTERIOR DOORS. FBC 107.3.4 - PROVIDE TWO |
| | SETS OF PRODUCT APPROVALS FOR THOSE PRODUCTS WHICH ARE |
| | REGULATED BY FAC 61G20-3.001 PER FLORIDA STATUTE |
| | 553.842 (5) THAT HAVE BEEN REVIEWED AND APPROVED IN |
| | WRITING BY THE DESIGNER OF RECORD. PROVIDE TWO COMPLETE |
| | PRODUCT APPROVALS WITH FL OR NOA NUMBERS INCLUDING |
| | INSTALLATION INSTRUCTIONS AND MAXIMUM DESIGN PRESSURES |
| | FOR EACH OF THE DIFFERENT ROOFING MATERIALS, WINDOW |
| | (GLASS TYPES), STRUCTURAL MULLIONS AND EXTERIOR DOOR |
| | TYPES. IDENTIFY THE SPECIFIC ITEMS AND THEIR DESIGN |
| | PRESSURES ON THE PRODUCT APPROVAL BY CIRCLING OR HIGH- |
| | LIGHTING THEM. THESE ITEMS CAN BE DEFERRED IF REQUESTED |
| | AND LISTED ON THE PLANS, HOWEVER, THE DOCUMENTS MUST BE |
| | SUBMITTED AND APPROVED BY THE BUILDING DEPARTMENT |
| | BEFORE THEY CAN BE INSTALLED. ONLY ONE SET IS REQUIRED |
| | TO BE UPLOADED FOR ELECTRONICALLY SUBMITTED DOCUMENTS. |
| | |
| | 7) SEPARATE APPLICATIONS AND PERMITS ARE REQUIRED FOR |
| | LANDSCAPING, FENCES, SITE WALLS, SIGNS, PARKING LOT |
| | WORK AND FABRIC AWNINGS. FBC 105 |
| | |
| | 8) SEE PLUMBING COMMENTS FOR FLORIDA ACCESSIBILITY |
| | COMMENTS. |
| | |
| | 9) PLEASE SUBMIT A RESPONSE LETTER INDICATING HOW EACH |