| Plan Review Notes For Permit 23030211 |
| Permit Number |
23030211 |
|
| Review Stop |
Z |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2023-04-11 16:20:31 | 4/11/2023 FAILED | | | | | | THE FRONT SETBACK IS REQUIRED TO BE A 25 FEET SETBACK | | | FROM THE PROPERTY LINE. | | | | | | CURRENTLY THE SETBACK IS NOT MEASURED FROM THE PROPERTY | | | LINE, IT SEEMS IT IS MEASURED FROM OUTSIDE THE PROPERTY | | | LINES | | | | | | |
|