| | 1ST REVIEW: FBC 2020 7TH EDITION |
| | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) |
| | FBC B = FBC BUILDING |
| | FBC R = FBC RESIDENTIAL |
| | FBC EB = FBC EXISTING BUILDING |
| | FBC A = FBC ACCESSIBILITY |
| | FBC EC = FBC ENERGY CONSERVATION |
| | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC |
| | RESULTS: DENIED |
| | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT |
| | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. |
| | |
| | 1. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT |
| | APPROVAL FL26482-R7 COVERS MULTIPLE PRODUCT TYPES; ROOF |
| | COVER OPTIONS; ALLOWABLE UNDERLAYMENT/TILE-ADHESIVE |
| | COMBINATIONS, ALLOWABLE SUBSTRATES & INSTALLATION |
| | METHODS. SELECT ALL APPLICABLE OPTIONS. ALL APPLICABLE |
| | DETAILS AND ATTACHMENTS MUST BE CLEARLY IDENTIFIED ON |
| | THE PRODUCT APPROVAL DRAWINGS. DETAILS AND ATTACHMENTS |
| | NOT SPECIFICALLY COVERED IN PRODUCT APPROVALS WILL NEED |
| | SITE-SPECIFIC ENGINEERING. |
| | 2. SUBMITTED PRODUCT APPROVAL FL5680-R35 HAS BEEN |
| | REVISED TO FL568-R36. PLEASE PROVIDE THE FOLLOWING: |
| | INCLUDE COVER PAGE, EVALUATION REPORT PAGES 1-6 AND |
| | INSTALLATION INSTRUCTIONS FOR SYSTEM USED. FL5680-R35 |
| | SYSTEM NO. W-55 DO NOT MEET THE MINIMUM ZONE 3 DESIGN |
| | PRESSURE REQUIREMENT OF -131.42 FOR EXPOSURE CATEGORY D |
| | AREAS. PROVIDE SYSTEM THAT MEETS OR EXCEEDS ALL DESIGN |
| | PRESSURE REQUIREMENTS FOR EXPOSURE CATEGORY D/PROVIDE |
| | SIGNED AND SEALED ENGINEERED NAILING CALCULATIONS WITH |
| | AN APPROVED SYSTEM. |
| | |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| | |