| Date |
Text |
| 2023-03-22 10:57:55 | RESIDENTIAL (R3 ) BUILDING REVIEW COMMENTS |
| | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. |
| | PERMIT #23021502 |
| | 521 46TH ST |
| | |
| | NOTE: |
| | LEVEL 1 ALTERATION. SEC. 602 FBC-EXISTING BUILDING. |
| | SEC. 702.6 FBC-EXISTING BUILDING. ALL NEW WORK SHALL |
| | COMPLY WITH THE MATERIALS AND METHODS REQUIREMENTS IN |
| | THE FLORIDA BUILDING CODE. |
| | |
| | 1-PROVIDE FLOOR PLAN OR SKETCH IDENTIFYING THE ROOMS |
| | WHERE WINDOWS ARE GOING TO BE REPLACED. FOR EXAMPLE: |
| | BEDROOM, LIVING AREA, ETC. SEC. 107.2.1 CITY |
| | AMENDMENTS. |
| | |
| | 2- SPECIFY SIZE AND TYPE OF EXISTING WINDOW AND SIZE |
| | AND TYPE OF PROPOSED WINDOWS TO VERIFY COMPLIANCE WITH |
| | THE EGRESS REQUIREMENTS OF SEC. 702.5 FBC-EXISTING |
| | BUILDING. |
| | |
| | 3- FBC-RESIDENTIAL SEC. 703.4, FBC- BUILDING SEC. |
| | 1405.4, A FLASHING DETAIL OR SPECIFICATION IS REQUIRED. |
| | THIS COMMENT CAN BE RESOLVED BY DOING ONE OF THE |
| | FOLLOWING: |
| | REVISE THE FLOOR PLAN TO NOTE THAT FLASHING IS REQUIRED |
| | AND NOTE THE CODE REFERENCE - EXAMPLE "FLASHING IN |
| | ACCORDANCE WITH FBC R 703.4/B 1405.4 WILL BE |
| | INSTALLED". |
| | PROVIDE A WRITTEN SPECIFICATION IN LETTER FORM - THIS |
| | MAY INCLUDE MORE THAN ONE OPTION |
| | PROVIDE A FLASHING DETAIL - THIS MAY INCLUDE MORE THAN |
| | ONE OPTION |
| | |
| | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE |
| | ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF WHERE AND |
| | HOW THE COMMENT WAS ADDRESSED WILL HELP TO EXPEDITE THE |
| | REVIEW PROCESS. THANK YOU FOR YOUR ANTICIPATED |
| | COOPERATION. |
| | |
| | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY |
| | QUESTIONS REGARDING THESE COMMENTS, |
| | JULIO GOMEZ |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | BUILDING DIVISION |
| | (561)805-6712 |
| | [email protected] |
| | |