| Plan Review Notes For Permit 23021305 |
| Permit Number |
23021305 |
|
| Review Stop |
P |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2023-03-10 13:37:04 | 1ST REVIEW FBC-2020 RES. PLUMBING | | | PERMIT- 23021305 | | | 3/10/23 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET 14 ACCESSORY STRUCTURE RISERS: THE RISER SHOWS | | | NO VENTING PROVIDED FOR THE BATHROOM FIXTURES- SECS. | | | P3101.2.1 FBC RES. IN ORDER TO CORRECT AND PROVIDE CODE | | | COMPLIANT VENTING PLEASE REFER TO SECS. P3108.1- | | | P3108.2.1 AND PROVIDE A DRY VENT FOR THE LAVATORY, AND | | | CONNECT THE LAVATORY FIXTURE TO THE BATHROOM BRANCH AT | | | A POINT EITHER UPSTREAM OR DOWNSTREAM OF THE SHOWER. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] |
|