| 2023-04-17 11:13:07 | AUDIT ON POOL PLAN REVIEW FAILED. |
| | |
| | 1) THE POOL BARRIER REQUIREMENT NEEDS TO BE RESOLVED. |
| | THERE IS NO RECORD OF AN EXISTING FENCE OR A PROPOSED |
| | POOL BARRIER FENCE FOR THIS PROPERTY. FBC- R4501.17 |
| | RESIDENTIAL SWIMMING BARRIER REQUIREMENT. RESIDENTIAL |
| | SWIMMING POOLS SHALL COMPLY WITH SECTIONS R4501.17.1 |
| | THROUGH R4501.17.3. EXCEPTION: A SWIMMING POOL WITH AN |
| | APPROVED SAFETY POOL COVER COMPLYING WITH ASTM F1346. |
| | |
| | 2) THE PROPOSED POOL ALARM ADDRESSES THIS REQUIREMENT. |
| | FBC- 4501.17.1.9 WHERE A WALL OF A DWELLING SERVES AS |
| | PART OF THE BARRIER, ONE OF THE FOLLOWING SHALL APPLY: |
| | 1. ALL DOORS AND WINDOWS PROVIDING DIRECT ACCESS FROM |
| | THE HOME TO THE POOL SHALL BE EQUIPPED WITH AN EXIT |
| | ALARM COMPLYING WITH UL 2017 THAT HAS A MINIMUM SOUND |
| | PRESSURE RATING OF 85 DBA AT 10 FEET (3048 MM). ANY |
| | DEACTIVATION SWITCH SHALL BE LOCATED AT LEAST 54 INCHES |
| | (1372 MM) ABOVE THE THRESHOLD OF THE ACCESS. SEPARATE |
| | ALARMS ARE NOT REQUIRED FOR EACH DOOR OR WINDOW IF |
| | SENSORS WIRED TO A CENTRAL ALARM SOUND WHEN CONTACT IS |
| | BROKEN AT ANY OPENING. |
| | EXCEPTIONS: |
| | A. SCREENED OR PROTECTED WINDOWS HAVING A BOTTOM SILL |
| | HEIGHT OF 48 INCHES (1219 MM) OR MORE MEASURED FROM THE |
| | INTERIOR FINISHED FLOOR AT THE POOL ACCESS LEVEL. |
| | B. WINDOWS FACING THE POOL ON FLOOR ABOVE THE FIRST |
| | STORY. |
| | C. SCREENED OR PROTECTED PASS-THROUGH KITCHEN WINDOWS |
| | 42 INCHES (1067 MM) OR HIGHER WITH A COUNTER BENEATH. |
| | 2. ALL DOORS PROVIDING DIRECT ACCESS FROM THE HOME TO |
| | THE POOL MUST BE EQUIPPED WITH A SELF-CLOSING, |
| | SELF-LATCHING DEVICE WITH POSITIVE MECHANICAL |
| | LATCHING/LOCKING INSTALLED A MINIMUM OF 54 INCHES (1372 |
| | MM) ABOVE THE THRESHOLD, WHICH IS APPROVED BY THE |
| | AUTHORITY HAVING JURISDICTION. |
| | 3. A SWIMMING POOL ALARM THAT, WHEN PLACED IN A POOL, |
| | SOUNDS AN ALARM UPON DETECTION OF AN ACCIDENTAL OR |
| | UNAUTHORIZED ENTRANCE INTO THE WATER. SUCH POOL ALARM |
| | MUST MEET AND BE INDEPENDENTLY CERTIFIED TO ASTM |
| | STANDARD F2208, TITLED "STANDARD SAFETY SPECIFICATION |
| | FOR RESIDENTIAL POOL ALARMS," WHICH INCLUDES SURFACE |
| | MOTION, PRESSURE, SONAR, LASER, AND INFRARED ALARMS. |
| | FOR PURPOSES OF THIS PARAGRAPH, THE TERM "SWIMMING POOL |
| | ALARM" DOES NOT INCLUDE ANY SWIMMING PROTECTION ALARM |
| | DEVICE DESIGNED FOR INDIVIDUAL USE, SUCH AS AN ALARM |
| | ATTACHED TO A CHILD THAT SOUNDS WHEN THE CHILD EXCEEDS |
| | A CERTAIN DISTANCE OR BECOMES SUBMERGED IN WATER. |
| | |
| | AUDITED BY: |
| | ROBERT MCDOUGAL, CBO |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | (561) 805-6714 |
| | [email protected] |
| | |
| | |
| | |