| Plan Review Notes For Permit 23021112 |
| Permit Number |
23021112 |
|
| Review Stop |
P |
| Sequence Number |
4 |
|
| Notes |
| Date |
Text |
| 2023-06-30 11:37:58 | 2ND REVIEW FBC-2020 RES. PLUMBING | | | PERMIT- 23021112 | | | 6/30/2023 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) AS PREVIOUSLY REQUESTED PLEASE PROVIDE A WRITTEN | | | SCOPE OF WORK FOR PLUMBING ON THE PLAN WITH | | | CORRESPONDING DETAILS. THE APPLICANT HAS RESPONDED TO | | | THE COMMENT WITH A LETTER RESPONSE WHICH HAS CLARIFIED | | | THE SCOPE OF WORK BUT THAT INFORMATION WAS ASKED TO BE | | | PLACED ON THE PLAN- SEC. 107.2.1 WPB. | | | PLEASE SHOW ON THE PLAN THE NEW LOCATIONS OF THE | | | ELECTRIC WATER HEATERS AND IDENTIFY ALL FIXTURES TO BE | | | REPLACED. IF NECESSARY PLEASE PROVIDE A SEPARATE | | | PLUMBING AND ELECTRICAL PLAN. THE ELECTRICAL DRAWING | | | SHALL SHOW THE NEW WIRING AND CIRCUITRY FOR THE | | | RELOCATED WATER HEATERS. PLEASE INCLUDE THE MAKES AND | | | MODELS OF THE WATER HEATERS AND NOTE DRAIN PANS AND | | | DRAIN LINES SHALL BE PROVIDED IN ACCORDANCE WITH | | | SEC.P2801.6- P2801.6.2 FBC RES. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | |
|