2023-07-17 08:23:153RD PLUMBING REVIEW
  
 THERE WERE NO CHANGES FROM THE PREVIOUS REVIEW. PLEASE
 ADDRESS COMMENTS BELOW.
  
 1. 2020 FRC P3101.2.1 - THE ISOMETRIC DOES NOT SHOW
 COMPLIANT VENTING METHODS. EACH BATHROOM DOES NOT SHOW
 A VENT ANYWHERE ON THE HORIZONTAL BRANCH FOR EITHER
 BATHROOM. THE WASHING MACHINE ALSO DOES NOT SHOW A
 VENT. PLEASE SHOW A CODE COMPLIANT VENTING
 CONFIGURATION.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
  