| Date |
Text |
| 2023-03-07 07:50:49 | 1ST REVIEW FMC |
| | PERMIT: 23020793 |
| | |
| | CODES IN EFFECT: 2020 |
| | |
| | FBC- FLORIDA BUILDING CODE |
| | FMC- FLORIDA MECHANICAL CODE |
| | FEC- FLORIDA ENERGY CONSERVATION |
| | FGC- FLORIDA FUEL GAS |
| | FEX- FLORIDA EXISTING BUILDING CODE |
| | FRC- FLORIDA RESIDENTIAL BUILDING CODE |
| | F.S.- FLORIDA STATUTES |
| | FAC- FLORIDA ACCESSIBILITY CODE |
| | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC |
| | |
| | PLAN REVIEW RESULTS: DENIED. |
| | |
| | 1) THIS ADDRESS IS A RETAIL STORE, THIS YOGA STUDIO |
| | WILL BE CHANGING THE USE FROM RETAIL TO BUSINESS. |
| | PROVIDE A CHANGE OF USE APPLICATION FOR THIS BUILDING. |
| | |
| | 2) THE NEW AHU-3 INFORMATION PACKET IS SHOWING ON PAGE |
| | 11 OF 13 THAT THE UNIT CHOSEN DOES NOT HAVE A HEATER |
| | INSTALLED. THE ENERGY CALCULATIONS FOR THIS AHU-3 IS |
| | SIZED FOR A TOTAL BTU LOAD OF HEAT REQUIRED AS 16,478. |
| | PLEASE SHOW THE REQUIRED HEAT FOR THIS UNIT. FEC |
| | C403.2.1 |
| | |
| | 3) PROVIDE THE OUTDOOR AIR CALCULATIONS BASED ON THE |
| | OCCUPANCY CLASSIFICATION OF EACH SPACE AND THE |
| | CORRESPONDING OCCUPANCY DENSITY FROM THAT MOST |
| | RESEMBLING THE USE OF SPACE FROM FMC TABLE 403.3.1.1 |
| | AND NOT THE ARCHITECTS EGRESS COUNT. FMC 403.3.1.1. |
| | |
| | 4) SHOW THE LOCATIONS OF THE OUTDOOR AIR INTAKE |
| | OPENINGS. FMC 401.4 |
| | |
| | 5) THE MECHANICAL DRAWING MUST SHOW ALL THE DOORS IN |
| | THE SPACE AND WINDOWS AND ENTRANCE AND EXIT DOORS. FBC |
| | 107.3.5 |
| | |
| | 6) PROVIDE THE SUPPLY CFM???S OF EACH AHU AND SHOW THE |
| | REQUIRED SMOKE DETECTORS AT THE SUPPLY SIDE OF EACH |
| | UNIT. FMC 606.1 |
| | |
| | 7) PROVIDE A ROOF DRAWING SHOWING THE LOCATION OF THE |
| | NEW AHU-3 CONDENSING UNIT AND THAT THE LOCATION WILL |
| | MEET THE GUARD REQUIREMENTS OF FMC 304.11 |
| | |
| | 8) SHOW THE CONDENSATE DISPOSAL LOCATIONS ON THE |
| | DRAWING. FMC 307.2.1 |
| | |
| | 9) THE BATH EXHAUST FANS TERMINATION MUST ALSO INCLUDE |
| | A SCREEN. FMC 501.3.2 |
| | |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM. |
| | |
| | MICHAEL EDWARDS |
| | MECHANICAL EXAMINER |
| | 401 CLEMATIS STREET |
| | WEST PALM BEACH FL. 33401 |
| | 561-805-6728 |
| | [email protected] |
| | |