Date Text
2023-03-13 13:31:13FLOOD ZONE AE. NFIP REVIEW:
  
 1- THIS BUILDING IS GOING TO BE BUILT IN A AE FLOOD
 ZONE WITH THE BASE FLOOD BFE:12.1 FEET BASED ON NAVD
 1988. CITY OF WEST PALM BEACH ORDINANCE REQUIRES A TWO
 (2) FOOT FREE BOARD ABOVE THE BASE FLOOD ELEVATION
 (SEC. 18-284 CITY ORDINANCE NO. 4729-17). THEREFORE,
 THE REQUIRED FINISH FLOOR ELEVATION IS 14.1 FEET MIN.
 NOTE: DESIGNER OF RECORD NEEDS TO SPECIFY THE PROPOSED
 FINISHED ELEVATION IN ALL ROOMS IN ALL FLOOR PLANS.
 ALSO, DESIGNER OF RECORD NEEDS TO SPECIFY THE FINISH
 ELEVATION ALL THE EQUIPMENT SERVING THE BUILDING. SEE
 SURVEY FOR EXISTING GRADE ELEVATIONS.
  
 DURING THE PERMITTING/CONSTRUCTION OF THIS STRUCTURE
 THREE DIFFERENT FLOOD ELEVATION CERTIFICATES WILL BE
 REQUIRED (SEC. 107.3.5.1.1 CITY AMENDMENTS):
 A) CONSTRUCTION DRAWINGS.
 B) BUILDING UNDER CONSTRUCTION.
 C) FINISHED CONSTRUCTION.
  
 NOTE:
 NEED TO PROVIDE THE CONSTRUCTION DRAWINGS ELEVATION
 CERTIFICATE NOW FOR REVIEW.