Plan Review Notes
Plan Review Notes For Permit 23020186
Permit Number 23020186
Review Stop B
Sequence Number 2
Notes
Date Text
2023-05-09 12:52:06JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM
 PHONE (561) 805-6656
 EMAIL: [email protected]
  
 1ST REVIEW: FBC 2020 7TH EDITION
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
 TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT
 CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX.
  
 1. FBC B 107.2.1 SUBMITTED PRODUCT APPROVAL FL5259-R37
 COVERS MULTIPLE ATTACHMENT LIMITATIONS. SELECTED
 ATTACHMENT LIMITATION SYSTEM USED FROM 5.8.3.2
 MECHANICALLY-ATTACHED BASE SHEET TABLE 4A ALLOWABLE
 DESIGN PRESSURES, DIRECT-T0-DECK UNDERLAYMENT IN TILE
 ROOF APPLICATIONS SYSTEM NO. UDL-13 DO NOT MEET OR
 EXCEED THE MINIMUM DESIGN PRESSURE REQUIREMENTS FOR A
 HIP ROOF; (6:12) ROOF SLOPE; MRH 15 FT. MINIMUM DESIGN
 PRESSURE REQUIREMENT OF -70 IN AN EXPOSURE CATEGORY C
 AREA. SELECT SYSTEM THAT MEETS OR EXCEEDS THIS
 REQUIREMENT. ALL APPLICABLE DETAILS AND ATTACHMENTS
 MUST BE CLEARLY IDENTIFIED ON THE PRODUCT APPROVAL
 DRAWINGS. PLEASE NOTE: SUBMITTED PRODUCT APPROVAL
 FL5259-R37 HAS BEEN REVISED TO FL5259-R38. PLEASE
 PROVIDE A COMPLETE SET TO INCLUDE COVER PAGE(S).
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  