Plan Review Notes
Plan Review Notes For Permit 23020134
Permit Number 23020134
Review Stop B
Sequence Number 1
Notes
Date Text
2023-02-15 11:56:54NEW SFR
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) PLEASE SHOW THE FINISHED FLOOR ELEVATION TO BE 2
 FOOT ABOVE FEMA BASE FLOOD ELEVATION -- CITY ORDINANCE
 NO. 4729-1 SEC. 18-33 - TECHNICAL AMENDMENTS TO FLORIDA
 BUILDING CODE, RESIDENTIAL.
 (A) R322.2.1 ELEVATION REQUIREMENTS. 1. BUILDINGS AND
 STRUCTURES IN FLOOD HAZARD AREAS NOT DESIGNATED AS
 COASTAL A ZONES SHALL HAVE THE LOWEST FLOORS ELEVATED
 TO OR ABOVE THE BASE FLOOD ELEVATION PLUS TWO
 FEET OR THE DESIGN FLOOD ELEVATION, WHICHEVER IS
 HIGHER.
  
 2) PLEASE SHOW THE FLOOD VENT SIZES AND LOCATIONS IF
 REQUIRED - FBC R322.2.2
  
 3) PLEASE PROVIDE A PROPOSED ELEVATION CERTIFICATE -
 FBC WPB 107.3.5.3
  
 4) PLEASE SHOW THE EQUIPMENT (AC, WATER HEATER ETC.)
 ELEVATIONS - FBC R322.1.6
  
 5) PLEASE SHOW THE STEP DOWN DIMENSIONS - FRONT ENTRY,
 SHOWER, GARAGE TO LIVING SPACE, PATIOS ETC.
  
 6) PLEASE SHOW THE TRUSS FLOOR/CEILING DRAFT STOP
 LOCATION AND TYPE - FBC R302.12
  
 7) PLEASE SHOW THE WINDOW SILL HEIGHT FOR THE OPERABLE
 WINDOWS WHICH MAY REQUIRE GUARDS - R312.2.1
  
 8) PLEASE PROVIDE DOCUMENTATION FOR THE SPRAY FOAM
 INSULATION - FBC R316.3 SURFACE BURNING
 CHARACTERISTICS.
 UNLESS OTHERWISE ALLOWED IN SECTION R316.5, FOAM
 PLASTIC OR FOAM PLASTIC CORES USED AS A COMPONENT IN
 MANUFACTURED ASSEMBLIES USED IN BUILDING CONSTRUCTION
 SHALL HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 75 AND
 SHALL HAVE A SMOKE-DEVELOPED INDEX OF NOT MORE THAN 450
 WHEN TESTED IN THE MAXIMUM THICKNESS AND DENSITY
 INTENDED FOR USE IN ACCORDANCE WITH ASTM E84 OR UL 723.
  
 9) PLEASE PROVIDE THE FLORIDA PRODUCT APPROVAL FRONT
 PAGES FOR PRODUCT APPROVAL FL7473-R9
  
 10) PLEASE CIRCLE THE ROOF TILE ATTACHMENT TO BE USED
 IN THE ROOF TILE PRODUCT APPROVAL - IF USING ADHESIVE
 PLEASE PROVIDE THE PRODUCT APPROVAL FOR THE ROOF TILE
 ADHESIVE.
  
 11) PLEASE SHOW THE STORM WATER FLOW AWAY FROM THE
 BUILDING AND AWAY FROM THE ADJACENT PROPERTY ON THE
 SITE PLAN OR PROVIDE A STORM WATER PLAN - FBC 107.2.5
 SITE PLAN. THE CONSTRUCTION DOCUMENTS SUBMITTED WITH
 THE APPLICATION FOR PERMIT SHALL BE ACCOMPANIED BY A
 SITE PLAN SHOWING TO SCALE THE SIZE AND LOCATION OF NEW
 CONSTRUCTION AND EXISTING STRUCTURES ON THE SITE,
 DISTANCES FROM LOT LINES, THE ESTABLISHED STREET GRADES
 AND THE PROPOSED FINISHED GRADES, DEPICTING THE
 PROPOSED LOT DRAINAGE AND, AS APPLICABLE, FLOOD HAZARD
 AREAS, FLOODWAYS, AND DESIGN FLOOD ELEVATIONS; AND IT
 SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE AND
 INCLUDED ON A BOUNDARY LINE SURVEY. (PLEASE PROVIDE CUT
 SECTIONS FOR ANY PROPOSED WATER RETAINING SWALES)
  
  
  
  