| Date |
Text |
| 2023-05-02 12:04:07 | 1ST REVIEW FBC-2020 RES. GAS |
| | PERMIT- 23020128 |
| | 5/2/23 |
| | |
| | CODES IN EFFECT: |
| | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION |
| | 2020 |
| | FS- FLORIDA STATUTES |
| | FAC- FLORIDA ADMINISTRATIVE CODE |
| | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC |
| | |
| | PLAN REVIEW RESULTS: DENIED. PLEASE REVIEWTHE COMMENTS |
| | AND NOTE THAT GAS CAN BE SUBMITTED UNFER A SEPARTATE |
| | PERMIT BY REQUEST. |
| | |
| | 1) SHEET E-1 SHOWS A GAS FIRED TANKLESS WATER HEATER IN |
| | THE PANEL SCHEDULE. PLEASE SUBMIT GAS PLANS- SEC. |
| | 107.2.1 WPB. AT A MINIMUM A GAS RISER DRAWING IS |
| | REQUIRED- SEC. 107.3.5.3 WPB. THE RISER SHALL INCLUDE |
| | ALL NEW AND EXISTING GAS PIPING AND APPLIANCES AT THE |
| | RESIDENCE- SECTION G2412.3 & G2412.4 FBC RES. REFER TO |
| | FBC RES. CHAPTER 24 FUEL GAS- THE RISER SHALL INDICATE: |
| | A) TYPE OF GAS- NATURAL OR LP. |
| | B) DELIVERY PRESSURE AT THE METER. |
| | C) TOTAL BTU LOAD AND INDIVIDUAL APPLIANCE BTU LOADS. |
| | D) TYPES AND SIZES OF PIPING. |
| | E) TOTAL DEVELOPED LENGTH OF THE SYSTEM FROM THE METER |
| | TO THE MOST REMOTE APPLIANCE OUTLET. |
| | F) BRANCH AND CUT PIPE LENGTH MEASUREMENTS. |
| | G) LOCATIONS OF REGULATORS, SHUTOFF VALVES. |
| | H) OUTLET PRESSURES AT REGULATORS. |
| | I) LOCATIONS AND TYPES OF PIPE SLEEVES. |
| | K) PIPE SIZING TABLES. |
| | |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. |
| | |
| | CHRISTOPHER L. COLE |
| | MECHANICAL/PLUMBING PLANS EXAMINER |
| | 401 CLEMATIS STREET |
| | WEST PALM BEACH FL 33401 |
| | 561-805-6719 |
| | [email protected] |
| | |