Plan Review Notes
Plan Review Notes For Permit 23020116
Permit Number 23020116
Review Stop P
Sequence Number 1
Notes
Date Text
2023-02-08 12:11:271ST REVIEW FBC-2020 RES. PLUMBING
 PERMIT- 23020116
 2/8/23
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET EP-1: THE PLUMBING DIAGRAMS DO NOT INDICATE
 THAT THE BUILDING DRAINS FOR THE LAUNDRY BUILDING AND
 FOR THE HOUSE HAVE AT LEAST ONE VENT PIPE EACH THAT
 EXTENDS TO THE OUTDOORS- SEC. P3102.1 FBC RES.
  
 2) EP-1: PROVIDE FIXTURE AND BRANCH DRAIN PIPE SIZES
 FOR THE KITCHEN SINK AND WASHING MACHINE- TABLES
 P3005.4.1 & P3201.7 FBC RES.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  