| Date |
Text |
| 2023-07-21 11:44:31 | NEW COMMERCIAL BUILDING |
| | REVIEWED BY ROGER MCPHERSON |
| | 561-805-6716 |
| | [email protected] |
| | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 |
| | AMENDMENT |
| | |
| | CORRECTIONS NEEDED - |
| | |
| | 1) PLEASE SHOW THE STORM WATER DRAINAGE AWAY FROM THE |
| | BUILDING AND AWAY FROM THE ADJACENT PROPERTY - PROVIDE |
| | THE CIVIL PLANS IF THEY WILL PROVIDE THE INFO NEEDED - |
| | PLEASE SHOW THE FOLLOWING ITEMS ON THE SITE PLAN PER - |
| | FBC WPB 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS |
| | SUBMITTED WITH THE APPLICATION FOR PERMIT SHALL BE |
| | ACCOMPANIED BY A SITE PLAN SHOWING TO SCALE THE SIZE |
| | AND LOCATION OF NEW CONSTRUCTION AND EXISTING |
| | STRUCTURES ON THE SITE, DISTANCES FROM LOT LINES, THE |
| | ESTABLISHED STREET GRADES AND THE PROPOSED FINISHED |
| | GRADES, DEPICTING THE PROPOSED LOT DRAINAGE AND, AS |
| | APPLICABLE, FLOOD HAZARD AREAS, FLOODWAYS, AND DESIGN |
| | FLOOD ELEVATIONS; AND IT SHALL BE DRAWN IN ACCORDANCE |
| | WITH AN ACCURATE AND INCLUDED ON A BOUNDARY LINE |
| | SURVEY. (PLEASE PROVIDE CUT SECTIONS FOR ANY PROPOSED |
| | WATER RETAINING SWALES) |
| | |
| | 2) PLEASE SHOW THE SOUTH EXTERIOR WALL TO BE 1 HR FIRE |
| | RATED PER - FBC TABLE 602 |
| | |
| | 3) PLEASE SHOW THE PERCENTAGE CALCULATIONS FOR THE |
| | EXTERIOR SOUTH WALL SQUARE FOOTAGE VERSES THE OPENINGS |
| | TO COMPLY WITH FBC 705.8.1 ALLOWABLE AREA OF OPENINGS. |
| | THE MAXIMUM AREA OF UNPROTECTED AND PROTECTED OPENINGS |
| | PERMITTED IN AN EXTERIOR WALL IN ANY STORY OF A |
| | BUILDING SHALL NOT EXCEED THE PERCENTAGES SPECIFIED IN |
| | TABLE 705.8. (PER STORY) |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |