| Date |
Text |
| 2023-02-13 15:24:16 | ELECTRIC REVIEW FAILED |
| | 1) PLAN PANEL SCHEDULE DETAILS LOCATION AS POOL HOUSE |
| | ADDITION. PLAN ALSO DETAILS POOL HOUSE AS THE SECOND |
| | PHASE OF THE PROJECT. TO PROVIDE CLARITY, PLEASE |
| | PROVIDE AN EXISTING ELECTRICAL RISER DETAILING SIZES |
| | AND LOCATIONS FOR ALL EXISTING METERS, DISCONNECTS, |
| | ELECTRIC PANELS. INCLUDE ALL CONDUIT AND CONDUCTOR |
| | SIZES. DETAIL THE GROUNDING ELECTRODE SYSTEM. PROVIDE |
| | PANEL SCHEDULES AND LOAD CALCULATIONS THAT ONLY INCLUDE |
| | EXISTING LOADS AND THE NEW LOADS ADDED IN THE CURRENT |
| | PROJECT. |
| | |
| | FBC 107.2, CONSTRUCTION DOCUMENTS SHALL BE OF |
| | SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND |
| | EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT |
| | WILL CONFORM TO THE PROVISIONS OF THIS CODE AND |
| | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS |
| | DETERMINED BY THE BUILDING OFFICIAL. |
| | |
| | NEC 215.5 DIAGRAMS OF FEEDERS. IF REQUIRED BY THE |
| | AUTHORITY HAVING JURISDICTION, A DIAGRAM SHOWING FEEDER |
| | DETAILS SHALL BE PROVIDED PRIOR TO THE INSTALLATION OF |
| | THE FEEDERS. |
| | |
| | 2) PROVIDE AN THE EXISTING FLOOR PLAN TO PROVIDE MORE |
| | CLARITY HOW NEW STRUCTURE WILL INTERFACE. IN ADDITION, |
| | PLEASE LOCATE ALL ELECTRIC PANELS AND METERS ON PLAN. |
| | FBC 107.2 |
| | |
| | 3) PLEASE DETAIL THE REQUIRED SMOKE/CARBON ALARM AS PER |
| | FBC R314/315 |
| | |
| | 4) VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS |
| | LOW. PROVIDE A BREAKDOWN OF ALL MATERIALS AND LABOR, |
| | OR, AT YOUR DISCRETION, PROVIDE A SIGNED CONTRACTOR |
| | PROVIDE A REASONABLE VALUE. WPB F.B.C. 109.3 |
| | |
| | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| | |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RESUBMITTAL FORM. |
| | |
| | CODES IN EFFECT: |
| | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION |
| | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| | BUILDING CODE 2020 7TH ED. |
| | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 |
| | 7TH EDITION |
| | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 |
| | 7TH EDITION |
| | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION |
| | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE |
| | FS = FLORIDA STATUTES |
| | |
| | V/R, |
| | |
| | MICHAEL PETERSON |
| | ELECTRICAL PLANS EXAMINER |
| | [email protected] |
| | 561-805-6746 |
| | |
| | |