| Plan Review Notes For Permit 23011342 |
| Permit Number |
23011342 |
|
| Review Stop |
B |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2023-03-17 12:57:26 | PETER E VALENTI | | | BUILDING PLANS EXAMINER II/INSPECTOR | | | [email protected] | | | 561 805 6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC M = FBC MECHANICAL | | | FBC FG = FBC FUEL GAS | | | | | | 2ND BUILDING REVIEW DENIED: | | | | | | FBC R 310.2.1, THE AREA FOR WINDOW OPENING #11 (WIDTH) | | | DOES NOT MEET THE MINIMUM REQUITREMENTS OF 20" AS THIS | | | OPENING IS FOR A BEDROOM (EGRESS). PLEASE RESUBMIT WITH | | | A WINDOW (CLEAR OPENING) THAT MEETS THE FOLLOWING | | | MINIMUM OPENING REQUIREMENTS: | | | | | | MINIMUM NET CLEAR OPENING: 5.7 S.F. | | | MINIMUM NET CLEAR HEIGHT: 24" | | | MINIMUM NET CLEAR WIDTH: 20" |
|