| Date |
Text |
| 2023-05-09 15:56:50 | 3RD REVIEW FBC-2020 PLUMBING |
| | PERMIT-23011309 |
| | 5/9/23 |
| | |
| | CODES IN EFFECT: |
| | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 |
| | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 |
| | FS- FLORIDA STATUTES |
| | FAC- FLORIDA ADMINISTRATIVE CODE |
| | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC |
| | |
| | PLAN REVIEW RESULTS: DENIED. |
| | |
| | 1) SHEET A101: IN RESPONSE TO COMMENT #1 (PRINTED BELOW |
| | FROM 1ST AND 2ND REVIEWS) FIXTURE CALCULATIONS HAVE |
| | BEEN ADDED TO SHEET A101, HOWEVER THE CHILDCARE |
| | OCCUPANT LOAD WAS NOT INCLUDED IN THE CALCULATIONS. |
| | PLEASE SEE SECTION 508.2.1 FBC B CONCERNING ACCESSORY |
| | OCCUPANCY COMPLIANCE- "THE REQUIREMENTS OF THIS CODE |
| | SHALL APPLY TO EACH PORTION OF THE BUILDING BASED ON |
| | THE OCCUPANCY CLASSIFICATION OF THAT SPACE." AS |
| | PREVIOUSLY NOTED SEPARATE FACILTIES ARE REQUIRED FOR |
| | THE 18 OCCUPANTS OF THE CHILDCARE ROOM- SEC. 403.2 FBC |
| | P. |
| | |
| | 1) 2ND REQUEST. SHEET G101: PROVIDE PLUMBING FIXTURE |
| | CALCULATIONS IN COMPLIANCE WITH TABLE 403.1 FBC P. THE |
| | OCCUPANT LOAD SUMMARY SHOWS A MIXED OCCUPANCY OF |
| | ASSEMBLY, BUSINESS, AND DAYCARE. REFER TO SEC. 403.1.1: |
| | FRACTIONAL NUMBERS FOR EACH OCCUPANCY SHALL FIRST BE |
| | SUMMED AND ROUNDED UP TO THE NEXT WHOLE NUMBER. IT |
| | APPEARS A SINGLE UNISEX TOILET ROOM HAS BEEN PROVIDED |
| | FOR THE DAY CARE HOWEVER SEPARATE FACILITIES FOR MALE |
| | AND FEMALE USE ARE REQUIRED- SEC. 403.2 FBC P. PLEASE |
| | NOTE THE FOLLOWING FIXTURE CALCULATIONS FOR FEMALE USE. |
| | ASSEMBLY- 328 FEMALE OCCUPANTS AT 1 PER 65 = 5.05 WATER |
| | CLOSETS |
| | BUSINESS- 42 FEMALE OCCUPANTS AT 1 PER 25 = 1.68 WATER |
| | CLOSETS |
| | TOTAL- 6.73 ROUNDS UP TO 7 WATER CLOSETS REQUIRED. THE |
| | PLAN SHOWS 6 FEMALE WATER CLOSETS PROVIDED IN THE GANG |
| | BATHROOM WHICH IS A DEFICIENCY OF ONE. |
| | |
| | |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. |
| | |
| | CHRISTOPHER L. COLE |
| | MECHANICAL/PLUMBING PLANS EXAMINER |
| | 401 CLEMATIS STREET |
| | WEST PALM BEACH FL 33401 |
| | 561-805-6719 |
| | [email protected] |
| | |