| Date |
Text |
| 2023-02-06 15:00:16 | 1ST BUILDING REVIEW |
| | RESULTS: CORRECTIONS NEEDED |
| | |
| | CHRISTOPHER S. THROOP, CBO, BN, PX, CFM |
| | PLANS EXAMINER II |
| | CITY OF WEST PALM BEACH |
| | (561) 805-6726 |
| | [email protected] |
| | |
| | CODES IN EFFECT: |
| | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST |
| | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, |
| | CHAPTER 1 ADMINISTRATION |
| | NFPA 70 2017 EDITION NEC 2017 |
| | |
| | ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT: |
| | |
| | 1.PROJECT IS LOCATED IN A SPECIAL FLOOD HAZARD AREA |
| | (SFHA). THE FLOOD ZONE DESIGNATION FOR THIS SITE IS AE |
| | WITH A BASE FLOOD ELEVATION (BFE) OF 6'0" NAVD. |
| | THE CITY OF WEST PALM BEACH (THROUGH ORDINANCE NO. |
| | 4729-17) REQUIRES AN ADDITIONAL 24 INCHES OF FREEBOARD. |
| | THE DESIGN FLOOD ELEVATION (DFE) SHALL BE AT OR ABOVE |
| | 8'0" NAVD. |
| | |
| | SUBMIT PLANS AND/OR DOCUMENTS TO SHOW COMPLIANCE WITH |
| | THE FBC R322.2 AND FEMA 50% RULE. |
| | |
| | ELEVATION CERTIFICATES REQUIRED. SEE NFIP REVIEW |
| | COMMENTS. |
| | |
| | 2.PROVIDE A COPY OF THE MOST RECENT BOUNDARY LINE |
| | SURVEY. |
| | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS |
| | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH |
| | 107.2.5. |
| | |
| | 3.PROVIDE THE DESIGN PRESSURES FOR NEW ROOFING PER |
| | FIGURE R301.2(7) COMPONENT AND CLADDING PRESSURE ZONES |
| | R301.2.1.1WIND DESIGN REQUIRED. |
| | RE-EVALUATE THE DESIGN PRESSURES FOR ZONE 3 ROOFING PER |
| | FBC RES TABLE R301.2(2). ROOF PITCH 5/12. ROOF SLOPE |
| | 22.6 DEGREES. EXPOSURE C. ADJUSTMENT COEFFICIENT 1.21. |
| | |
| | 4.PROVIDE A ROOF SHEATHING FASTENER SCHEDULE PER THE |
| | ENHANCED CALCULATED DESIGN PRESSURES OF ZONES 2 AND 3. |
| | TABLE R301.2.1.2 WINDBORNE DEBRIS PROTECTION FASTENING |
| | SCHEDULE FOR WOOD STRUCTURAL PANELS. |
| | |
| | 5. PROVIDE SHOP DRAWINGS, REVIEWED AND APPROVED FOR |
| | ALUMINUM STAIRS. |
| | 107.2 CONSTRUCTION DOCUMENTS SHALL BE IN ACCORDANCE |
| | WITH SECTIONS107.2.1 THROUGH 107.2.5. |
| | |
| | 6.PROVIDE LOCATION OF ATTIC ACCESS PER R807.1.7. |
| | R807.1.7 BUILDINGS WITH COMBUSTIBLE CEILING OR ROOF |
| | CONSTRUCTION SHALL HAVE AN ATTIC ACCESS OPENING TO |
| | ATTIC AREAS THAT HAVE A VERTICAL HEIGHT OF 30 INCHES |
| | (762 MM) OR GREATER OVER AN AREA OF NOT LESS THAN 30 |
| | SQUARE FEET (2.8 M2). |
| | |
| | 7.PROVIDE A WINDOW AND DOOR FLASHING DETAIL OR THE |
| | SPEC. SHEET OF A FLUID APPLIED MEMBRANE. |
| | R703.4 |
| | |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| | |
| | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |