| 2023-03-09 16:58:24 | 1ST REVIEW FBC-2020 RES. PLUMBING | | | PERMIT- 23010438 | | | 3/9/23 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET M1: THE SANITARY ISOMETRIC IS TENTATIVELY | | | APPROVED HOWEVER THE PRINTED NAME AND SIGNATURE OF THE | | | DESIGNER SHALL BE ON THE PLAN SHEET FOR FINAL APPROVAL- | | | SEC. 107.2.1 WPB. | | | | | | 2) SHEET A3.0 WHICH CONTAINS A PLUMBING PLAN AND | | | ISOMETRIC DRAWING APPEARS TO HAVE BEEN UPLOADED BY | | | MISTAKE BECAUSE IT IS A REMODELING PLAN WITH A | | | COMPLETELY DIFFERENT FLOOR PLAN THAN THE NEW HOUSE PLAN | | | SHOWN A1.0. I HAVE LOCKED THE PLAN OUT FROM REVIEW- | | | SEC. 107.2.1 WPB. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|