| Date |
Text |
| 2023-01-12 12:03:37 | SIGNATURE REVIEW FBC- 2020 |
| | PERMIT- 23010405 |
| | 1/12/23 |
| | |
| | CODES IN EFFECT: |
| | FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020 |
| | FS- FLORIDA STATUTES |
| | FAC- FLORIDA ADMINISTRATIVE CODE |
| | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC |
| | |
| | PLAN REVIEW RESULTS: DENIED. |
| | |
| | 1) THE ENGINEER???S ROOF FASTENING CALCULATION DOCUMENT |
| | APPEARS TO BE A SCANNED COPY OF THE ORIGINAL DOCUMENT |
| | WITH A COPIED SIGNATURE AND SEAL BY THE ENGINEER OF |
| | RECORD. PLANS AND DOCUMENTS PREPARED BY FL. LICENSED |
| | ENGINEERS THAT ARE TRANSMITTED ELECTRONICALLY SHALL |
| | BEAR VERIFIABLE DIGITAL SIGNATURES AND SEALS OF THE |
| | ENGINEER- FL. STATUTE 471.025, AND SECTION 61G15-23.005 |
| | FAC. |
| | |
| | FLORIDA BOARD OF PROFESSIONAL ENGINEERS GUIDELINES FOR |
| | ELECTRONIC OR DIGITALLY SIGNED AND SEALED PLANS AND |
| | DOCUMENTS. |
| | A DIGITAL SIGNATURE MUST BE UNIQUE TO THE PROFESSIONAL |
| | ENGINEER USING IT, OBTAINED FROM A THIRD-PARTY |
| | CERTIFICATION AUTHORITY, AND CAPABLE OF VERIFICATION. |
| | THE CERTIFICATION AUTHORITY WILL VET THE PE AND PROVIDE |
| | A PASSWORD-PROTECTED DIGITAL SIGNATURE FILE. (FBPE DOES |
| | NOT APPROVE OR PROVIDE A LIST OF AUTHORITIES.) |
| | YOU MAY NOT USE THE DIGITAL OPTION PROVIDED IN ADOBE |
| | ACROBAT, SINCE IT IS SELF-AUTHENTICATED AND DOES NOT |
| | USE A THIRD PARTY. |
| | YOUR DIGITAL SIGNATURE MUST BE LINKED TO THE DOCUMENT |
| | IN SUCH A WAY THAT ANY CHANGE INVALIDATES THE SIGNATURE |
| | AND DOCUMENT. |
| | |
| | CHRISTOPHER L. COLE |
| | MECHANICAL/PLUMBING PLANS EXAMINER |
| | 401 CLEMATIS STREET |
| | WEST PALM BEACH FL 33401 |
| | 561-805-6719 |
| | [email protected] |
| | |