2023-02-07 14:07:25FAILED
 2/7/2023
  
 PROPOSED SINGLE FAMILY HOME IS OVER THE MAXIMUM HEIGHT
 ALLOWANCE FOR SINGLE FAMILY LOW DENSITY (SF7) ZONING
 (HEIGHT IS MEASURED FROM GRADE)
 ARTICLE III. SECTION 94-72
  
 NEW CONSTRUCTIONS ARE REQUIRED TO HAVE A SEPARATE
 LANDSCAPE PERMIT IN THE SYSTEM.
 PLEASE REACH OUT TO SMITH AMISIAL (LANDSCAPE PLANNER)
 561-822-1562
  
 WHERE THE OUTDOOR SHOWER IS LOCATED THERE IS TWO DOORS
 FOR THE BATHROOM AND A MECHANICAL ROOM THOSE DOORS ARE
 CURRENTLY SHOWING THAT THEY ARE 5FT ABOVE GRADE WITH NO
 STEPS?
 ARTICLE X SECTION 94-305
 STEPS AND PORCHES. STEPS, OPEN UNCOVERED PORCHES OR
 STOOPS, AND OPEN TERRACES WHICH ARE THREE FEET OR LESS
 ABOVE GRADE MAY ENCROACH INTO ANY REQUIRED SETBACK AREA
 TO A POINT NOT CLOSER THAN TWO FEET TO THE PROPERTY
 LINE. ANY GRADE DIFFERENTIAL BETWEEN THE ENCROACHING
 STEP, PORCH, STOOP, OR TERRACE AND ADJACENT PROPERTY
 SHALL BE STRUCTURALLY RETAINED AND POSITIVELY DRAINED
 IN A MANNER THAT WILL PREVENT ANY DRAINAGE DISCHARGE TO
 ANY PROPERTY CONTIGUOUS TO THE SIDE OR REAR PROPERTY
 LINES.
  
  
 SEPARATE PERMIT REQUIRED AND NOT IN INCLUDE IN THIS
 PERMIT:
  
 DRIVEWAYS
 THERE IS A 3FT MINIUM BUFFER FROM THE PROPERTY LINE TO
 WHERE THE DRIVEWAY CAN BE LOCATED PLEASE LABEL THIS
 SETBACK FOR THE DRIVEWAY LOCATED ON BLOOMFIELD DRIVE
 THE LESSER OF 1,000 SQUARE FEET OR 75 PERCENT OF THE
 FRONT YARD AREA SHALL BE LANDSCAPED WITH LIVING PLANT
 MATERIAL (SUCH AS GRASS, GROUND COVER, SHRUBS, HEDGES,
 VINES OR TREES).
 ATRICLE XV. SECTION 94-482
 * FLAGLER DRIVE IS CONSIDERED YOUR FRONT
  
 VISIBILTY TRIANGLE IS REQUIRED PLEASE LABEL THE
 DIMENTIONS OF THE TRIANGLE ON PLANS.
 VISIBILITY AT INTERSECTIONS. AT ANY ROAD INTERSECTIONS,
 VISIBILITY SHALL NOT BE OBSCURED BY THE CONSTRUCTION,
 PLACEMENT, OR MAINTENANCE OF A STRUCTURE WALL, SIGN,
 FENCE, BERM, PLANT MATERIAL, SHRUBS, OR ANY SIMILAR
 ITEM BETWEEN 18 INCHES OR EIGHT FEET IN HEIGHT WITHIN A
 TRIANGLE BEGINNING AT THE POINT WHERE PROPERTY LINES
 MEET AT THE CORNER, THEN 20 FEET ALONG THE FRONT
 PROPERTY LINE, THENCE DIAGONALLY TO A POINT ALONG THE
 SIDE PROPERTY LINE 20 FEET FROM THE POINT OF BEGINNING,
 AND THENCE TO THE POINT OF BEGINNING. IN THE EVENT THE
 CORNER OF AN INTERSECTION IS ROUNDED, THE MEASUREMENT
 SHALL BEGIN AT THE POINT THE PROPERTY LINES WOULD MEET
 WITHOUT ROUNDING.
 ATRICLE X. SECTION94-305
  
 MECHANICAL/POOL EQUIPMENT/GENERATOR
 EQUIPMENT MAY NOT PROJECT MORE THAN FOUR FEET INTO A
 SETBACK.
 ARTICLE X SECTION 94-305
  
  
 ALEXIS SANGELEER
 PLANNER
 [email protected]
  
  
  