Notes
Date Text
2023-07-27 09:13:30NEW 2 STORY APARTMENT BUILDING
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) DRAWINGS A-2.1 THE SOUTH ELEVATION APPEARS TO HAVE
 THE 2ND FLOOR STAIR ON THE WRONG SIDE.
  
 2) DRAWING A-2.2 THE NORTH ELEVATION APPEARS TO HAVE
 THE 2ND FLOOR STAIR ON THE WRONG SIDE.
  
 3) DRAWING S.4.3 AND S.4.4 - THE NORTH AND SOUTH
 ELEVATIONS APPEAR TO BE SWITCHED.
  
 4) DRAWING S.4.3 SHOWS WINDOWS ON THE SOUTH SIDE OF THE
 BUILDING - THE ARCHITECTURALS DO NOT SHOW WINDOWS ON
 THE SOUTH SIDE - THE DRAWINGS SHOULD MATCH.
  
 5) DRAWING SP-1 APPEARS TO SHOW A CURB CUT AT THE
 BOTTOM OF THE RAMP NEXT TO THE PARKING LOT - CANNOT
 HAVE A CURB CUT IN A RAMP LANDING - FBC A 405.7.1
 SLOPE. LANDINGS SHALL COMPLY WITH 302. CHANGES IN LEVEL
 ARE NOT PERMITTED.
 405.7.3 LENGTH. THE LANDING CLEAR LENGTH SHALL BE 60
 INCHES (1525 MM) LONG MINIMUM.
  
 6) DRAWING SP-1 - THE 3 FOOT LONG RAMP BETWEEN THE
 STAIR AND DUMPSTER ENCLOSURE NEEDS A 5 FOOT LANDING -
 FBC A 405.7 LANDINGS.
 RAMPS SHALL HAVE LANDINGS AT THE TOP AND THE BOTTOM OF
 EACH RAMP RUN. LANDINGS SHALL COMPLY WITH 405.7.
  
  
  
  
  
  
  
  
  
  
  
  
  
  