Plan Review Notes
Plan Review Notes For Permit 23010083
Permit Number 23010083
Review Stop B
Sequence Number 2
Notes
Date Text
2023-06-22 15:17:29BUILDING REVIEW APPROVED WITH PROVISO (PER ARCHITECT'S
 REQUEST):
 (NOTE: PROVIDE INFORMATION FOR REVIEW PRIOR TO
 INSPECTIONS TO AVOID CONFLICTS/DELAYS):
 1- PROVIDE COMPLETE DETAILS/SPECIFICATIONS FOR THE
 ELEVATOR INSTALLATION UNDER A SEPARATE PERMIT.
 2- REVISE ROOF SHEATHING NAIL SPACING SPECS. 4 INCHES
 O.C. TABLE R803.2.3.1 FBC-RESIDENTIAL.
 3- REVISE WOOD FRAMED WALLS SPECS: NEED 2 LAYERS OF
 WATER RESISTIVE BARRIERS.
 4- NEED CARBON MONOXIDE ALARM WITHIN 10 FEET OF BEDROOM
 #1.
 5- CRAWL SPACE VENTS. SHOW COMPLIANCE WITH VENT
 LOCATION & ACCESS. SEC. R408.2 AND SEC. R408.4
 FBC-RESIDENTIAL.
 6- SPECIFY SIZE OF HORIZONTAL MULLION FOR WINDOW #9.
 AND MARK SIZE IN PRODUCT APPROVAL.
 7- RESUBMIT CASEMENT WINDOWS, FIXED WINDOWS, WINDOW
 MULLIONS, SINGLE HUNG WINDOWS AND FRENCH DOORS PRODUCT
 APPROVALS. THEY WERE REVISED AND WERE NOT APPROVED BY
 THE ARCHITECT.
 8- COORDINATE AND RESUBMIT ALL ROOFING PRODUCT
 APPROVALS AFTER THIS BUILDING PERMIT IS ISSUED. SOME
 PRODUCT APPROVALS WERE MISMATCHED, AND SOME WERE NOT
 APPROVED BY THE ARCHITECT.