| 2023-01-19 14:29:17 | 1ST REVIEW FMC | | | PERMIT: 22121422 | | | | | | CODES IN EFFECT: 2020 | | | | | | FBC- FLORIDA BUILDING CODE | | | FMC- FLORIDA MECHANICAL CODE | | | FEC- FLORIDA ENERGY CONSERVATION | | | FGC- FLORIDA FUEL GAS | | | FEX- FLORIDA EXISTING BUILDING CODE | | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | | F.S.- FLORIDA STATUTES | | | FAC- FLORIDA ACCESSIBILITY CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET 10 OF 15: A FLORIDA LICENSED MECHANICAL | | | CONTRACTOR SHALL APPLY FOR A MECHANICAL SUB-PERMIT AND | | | PROVIDE THE MANUAL J AND MANUAL S CALCULATIONS FOR THIS | | | MODULAR HOME. | | | | | | 2) PROVIDE A DRAWING INDICATING WHERE THE CONDENSING | | | UNIT WILL BE LOCATED AND HOW IT WILL BE SECURED. FBC | | | 107.3.5 | | | | | | 3) ON THE RESCHECK COMPLIANCE CERTIFICATE SUBMITTED THE | | | SEER RATING IS 14, THIS PROJECT WAS SUBMITTED AFTER | | | JAN. 01, 2023. PLEASE SHOW THAT THE SEER RATING MEETS | | | THE NEW FEDERAL GUIDELINES ADOPTED 01/01/2023 | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|