Plan Review Notes
Plan Review Notes For Permit 22121353
Permit Number 22121353
Review Stop B
Sequence Number 1
Notes
Date Text
2023-02-10 15:17:47NEW SFR
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) DRAWING CS0.00 - SHOWS THE 2017 FBC USED - NEEDS TO
 BE PER 2020 FBC
  
 2) PLEASE SHOW THE ATTIC ACCESS LOCATION AND SIZE PER
 FBC R807.1
  
 3) PLEASE PROVIDE AN INTERIOR DOOR SCHEDULE - FBC
 R320.1.1
 ALL NEW SINGLE-FAMILY HOUSES, DUPLEXES, TRIPLEXES,
 CONDOMINIUMS AND TOWNHOUSES SHALL PROVIDE AT LEAST ONE
 BATHROOM, LOCATED WITH MAXIMUM POSSIBLE PRIVACY, WHERE
 BATHROOMS ARE PROVIDED ON HABITABLE GRADE LEVELS, WITH
 A DOOR THAT HAS A 29-INCH (737 MM) CLEAR OPENING.
 HOWEVER, IF ONLY A TOILET ROOM IS PROVIDED AT GRADE
 LEVEL, SUCH TOILET ROOMS SHALL HAVE A CLEAR OPENING OF
 NOT LESS THAN 29 INCHES
  
 4) WINDOW AND DOOR PRODUCT APPROVALS NEED TO BE
 REVIEWED AND MARKED APPROVED BY THE BUILDING DESIGNER
 OF RECORD - FBC WPB 107.3.4
  
 5) HARDI - BOARD SIDING IS SUBJECT TO WIND LOADS -
 PLEASE PROVIDE ATTACHMENT DETAILS ON THE DRAWINGS OR
 PROVIDE A PRODUCT APPROVAL FOR THE HARDI - BOARD SIDING
 - FBC R703.1.2
  
 6) PLEASE PROVIDE THE ICC EVALUATION REPORT FOR THE
 ICYNENE FOAM INSULATION - FBC R316
  
 7) PLEASE SHOW ON THE SITE PLAN THE STORM WATER FLOW
 AWAY FROM THE BUILDING AND AWAY FROM THE ADJACENT
 PROPERTY OR PROVIDE A STORM WATER PLAN - FBC WPB
 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS SUBMITTED
 WITH THE APPLICATION FOR PERMIT SHALL BE ACCOMPANIED BY
 A SITE PLAN SHOWING TO SCALE THE SIZE AND LOCATION OF
 NEW CONSTRUCTION AND EXISTING STRUCTURES ON THE SITE,
 DISTANCES FROM LOT LINES, THE ESTABLISHED STREET GRADES
 AND THE PROPOSED FINISHED GRADES, DEPICTING THE
 PROPOSED LOT DRAINAGE AND, AS APPLICABLE, FLOOD HAZARD
 AREAS, FLOODWAYS, AND DESIGN FLOOD ELEVATIONS; AND IT
 SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE AND
 INCLUDED ON A BOUNDARY LINE SURVEY. (PLEASE PROVIDE CUT
 SECTIONS FOR ANY PROPOSED WATER RETAINING SWALES)
  
 8) SIGNED AND SEALED DRAWINGS DO NOT SHOW AS DIGITALLY
 SIGNED IN ADOBE READER - SIGNED AND SEALED DRAWINGS IN
 PROJECTDOX NEED TO BE DIGITALLY/ELECTRONICALLY SIGNED
 TO BE USED IN ELECTRONIC PLAN REVIEW. (A
 CERTIFICATE-BASED DIGITAL SIGNATURE (OFTEN JUST CALLED
 A DIGITAL SIGNATURE) IS A SPECIFIC TYPE OF
 E-SIGNATURE).
  
 9) PLEASE PROVIDE A SURVEY.