| 2023-06-16 14:29:12 | SEVENTH BUILDING REVIEW COMMENTS |
| | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. |
| | PERMIT #22120578 |
| | 6200 S DIXIE HWY |
| | |
| | NEW COMMENT BASED ON DRAWINGS SUBMITTED: |
| | |
| | 1- THE DESIGN CRITERIA SHOWN ON THE RIGHT HAND SIDE OF |
| | ALL THE DRAWINGS DOESN'T MATCH THE DESIGN CRITERIA |
| | CONSIDERED IN THE CALCULATIONS FOR THE FREE STANDING |
| | SIGNS SUBMITTED. ENGINEER TO REVISE INFORMATION AS |
| | REQUIRED TO MATCH |
| | SEC. 1603.1.4 FBC-BUILDING, SEC. 1609.1 FBC-BUILDING. |
| | |
| | 2- DIGITAL SIGNATURE: ENGINEER'S DIGITAL SIGNATURE |
| | DOESN'T COMPLY WITH THE REQUIREMENTS OF FBPE. |
| | |
| | A) THE TEXT BOX LANGUAGE MUST NOT BE A PART OF THE |
| | DIGITAL SIGNATURE ITSELF. |
| | SEE FBPE.ORG/LEGAL/SIGNING-AND-SEALING-ENGINEERING-DOCU |
| | MENTS/ AND REVISE AS REQUIRED. |
| | |
| | B) THE TEXT BOX LANGUAGE MUST BE IDENTICAL TO THE |
| | SAMPLES PUBLISHED BY FBPE. SEE FBPE.ORG/LEGAL/SIGNING-A |
| | ND-SEALING-ENGINEERING-DOCUMENTS/ AND REVISE AS |
| | REQUIRED TO MATCH. |
| | |
| | 61G15-23.004 PROCEDURES FOR DIGITALLY SIGNING AND |
| | SEALING ELECTRONICALLY TRANSMITTED PLANS, |
| | SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS. |
| | |
| | NOTE: |
| | THESE COMMENTS WERE VERIFIED WITH THE FBPE |
| | INVESTIGATOR. THE TEXT BOX REQUIREMENTS APPLY |
| | |
| | |
| | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE |
| | ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF WHERE AND |
| | HOW THE COMMENT WAS ADDRESSED WILL HELP TO EXPEDITE THE |
| | REVIEW PROCESS. THANK YOU FOR YOUR ANTICIPATED |
| | COOPERATION. |
| | |
| | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY |
| | QUESTIONS REGARDING THESE COMMENTS, |
| | |
| | JULIO GOMEZ |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | BUILDING DIVISION |
| | (561)805-6712 |