| Plan Review Notes For Permit 22120465 |
| Permit Number |
22120465 |
|
| Review Stop |
B |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2023-03-07 12:56:32 | NEW SFR ACCESSORY STRUCTURE | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) ATTIC ACCESS ON THE DRAWINGS IS SHOWN AS 24X24 - | | | PLEASE SHOW THE ATTIC ACCESS SIZE PER - FBC R807.1 THE | | | ROUGH-FRAMED OPENING SHALL BE NOT LESS THAN 22 INCHES | | | BY 30 INCHES (559 MM BY 762 MM) AND SHALL BE LOCATED IN | | | A HALLWAY OR OTHER LOCATION WITH READY ACCESS. | | | | | | 2) ALL PRODUCT APPROVALS NEED TO BE REVIEWED AND MARKED | | | APPROVED BY THE BUILDING DESIGNER OF RECORD - FBC WPB | | | 107.3.4 | | | | | | 3) THE PROVIDED APPROVED LIST OF PRODUCT APPROVALS FROM | | | THE ARCHITECT IS MISSING SOME OF THE PRODUCT APPROVALS | | | THAT ARE UPLOADED TO PROJECTDOX AND SOME OF THE PRODUCT | | | APPROVALS IN PROJECTDOX ARE NOT LISTED ON THE PRODUCT | | | APPROVAL LIST FROM THE ARCHITECT. THE LISTED PRODUCT | | | APPROVALS SHOULD MATCH THE PRODUCT APPROVALS LOADED | | | INTO PROJECTDOX. PLEASE REVIEW THE LIST AND THE PRODUCT | | | APPROVALS UPLOADED TO PROJECTDOX. IF NEEDED PLEASE E | | | MAIL THE PERMIT LIBRARIAN TO REMOVE PRODUCT APPROVALS | | | NOT NEEDED OR NOT LISTED ON THE APPROVED LIST FROM THE | | | ARCHITECT. | | | | | | | | | | | | |
|