2023-01-18 18:22:08RESIDENTIAL (R2) SECOND BUILDING REVIEW COMMENTS
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #22120391
 600 S DIXIE HWY # 504
  
  
 1-FLOORING SOUND INSULATION MATERIAL:
  
 ORIGINAL COMMENT:
 (A)PROVIDE COPY OF THE FLAME SPREAD INDEX AND SMOKE
 DEVELOPED INDEX TEST DONE IN ACCORDANCE WITH ASTM E 84
 OR UL 723 AS REQUIRED BY SEC. 720.1 OF FBC 7TH EDITION
 (2020).
  
 RESPONSE:
 UNDERLAYMENT FLAME SPREAD INDEX AND SMOKE DEVELOPED
 INDEX TEST WAS NOT SUBMITTED.
  
 ORIGINAL COMMENT:
 (B)PROVIDE COPY OF THE SOUND TRANSMISSION CLASS (STC)
 TEST DONE IN ACCORDANCE WITH ASTM E 90 AS REQUIRED BY
 SEC. 1207.2 OF FBC 7TH EDITION (2020).
  
 RESPONSE:
 TEST SUBMITTED IS FOR LAMINATED WOOD OVER PROFLEX LV200
 UNDERLAYMENT. THE PERMIT APPLICATION CALLS FOR VINYL
 FLOORING. NEED TEST REPORT FOR VINYL FLOORING OVER
 PROFLEX LV200 UNDERLAYMENT.
  
 ORIGINAL COMMENT:
 (C)PROVIDE COPY OF THE IMPACT INSULATION CLASS (IIC)
 TEST DONE IN ACCORDANCE WITH ASTM E 492 AS REQUIRED BY
 SEC. 1207.3 OF FBC 7TH EDITION (2020).
  
 RESPONSE:
 TEST SUBMITTED IS FOR LAMINATED WOOD OVER PROFLEX LV200
 UNDERLAYMENT. THE PERMIT APPLICATION CALLS FOR VINYL
 FLOORING. NEED TEST REPORT FOR VINYL FLOORING OVER
 PROFLEX LV200 UNDERLAYMENT.
  
 NOTE: TEST SAMPLES TO MATCH BUILDING FLOOR/CEILING
 CONSTRUCTION AND PROPOSED FLOOR FINISH. ALSO, THERE ARE
 TESTS FOR 6" OR 8" CONCRETE SLABS WITH OR WITHOUT
 ACOUSTICAL CEILING. TYPICALLY THERE ARE NOT SUSPENDED
 ACOUSTICAL CEILINGS IN THESE BUILDINGS.
  
 PLEASE NOTE THAT TEST REPORTS ARE REQUIRED -
 MANUFACTURER SPEC SHEETS ARE NOT ACCEPTABLE DUE TO
 DISCREPANCIES BETWEEN SPEC SHEETS/BROCHURES AND TEST
 REPORTS FOR SOME MANUFACTURERS (NOT NECESSARILY THE
 MANUFACTURER SELECTED; THIS IS A GENERAL COMMENT)
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  