| Plan Review Notes For Permit 22111251 |
| Permit Number |
22111251 |
|
| Review Stop |
P |
| Sequence Number |
3 |
|
| Notes |
| Date |
Text |
| 2023-04-17 15:03:22 | 2ND PLUMBING REVIEW | | | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | | | 1. DONE | | | | | | 2. DONE | | | | | | 3. CORRECTION DOES NOT COMPLY - THE MIXING VALVE MUST | | | BE INSTALLED AT THE HOT WATER SOURCE, NOT AT THE MOP | | | SINK. 2020 FPC 613.1 | | | | | | CORRECTION DOES NOT FULLY COMPLY WITH THE CODE SECTION | | | - "ALL" HOT WATER MUST BE LIMITED BY A MIXING VALVE. IF | | | YOU WANT 140 AS WELL AS 120, THEN TWO MIXING VALVES ARE | | | NEEDED. CURRENTLY, THE 140 GOING TO THE MOP SINK IS | | | ONLY LIMITED BY THE THERMOSTAT ON THE WATER HEATER. PER | | | THE CODE SECTION - "THE THERMOSTAT FOR THE WATER HEATER | | | SHALL NEVER BE THE LIMITING DEVICE FOR HOT AND/OR | | | TEMPERED WATER DELIVERY". | | | PROVIDE A TEMPERATURE-ACTUATED MIXING VALVE COMPLYING | | | WITH ASSE 1017 AT THE WATER HEATER. FBC PL 607.1.1, | | | 613.1 | | | | | | 4. DONE | | | | | | 5. DONE | | | | | | 6. DONE | | | | | | RYAN W. BROWN | | | CHIEF PLUMBING INSPECTOR | | | OFFICE: 561-805-6692 | | | CELL: 561-517-4293 | | | EMAIL: [email protected] | | | | | | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | | V7 FGC - 2020 FLORIDA FUEL GAS | | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE | | | V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE | | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | | 2021 F.S. - 2021 FLORIDA STATUTES | | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | | FBC CHAPTER 1 | | | | | | |
|