Plan Review Notes
Plan Review Notes For Permit 22111176
Permit Number 22111176
Review Stop B
Sequence Number 4
Notes
Date Text
2023-07-25 10:41:28WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 22111176
 ADD: 424 PARK PLACE # 442 PCN: 74-43-43-28-06-001-0011
 CONT: GNEISS CORPORATION
 TEL: 561-797-5274
 E-MAIL: [email protected]
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 3RD REVIEW
 DATE: TUES. MARCH 14TH/2023
 ACTION: DENIED
  
 1A) COMPLIED. ADDRESS & OVERALL BUILDING PLAN.
  
 1B) COMPLIED. INDEX.
  
 2) 4TH REQUEST, THE VALUE IS STILL LOW AT $17,500.00
 DOLLARS. 2ND REQUEST NOT ADDRESSED; VALUE IS NOW LOW.
 THE PERMIT APPLICATION DESCRIPTION OF WORK IS LEFT
 BLANK, THE DOLLAR AMOUNT GIVEN FOR THIS PERMIT IS
 $17,500.00 DOLLARS. 2020 WEST PALM BEACH AMENDMENTS TO
 THE FLORIDA BUILDING CODE, CHAPTER 1, ADMINISTRATION
 107.2.1. CONSTRUCTION DOCUMENTS SHALL BE SUFFICIENT
 CLARITY TO INDICATE THE LOCATION, NATURE AND EXTENT OF
 THE WORK PROPOSED AND SHOW IN DETAIL THAT IT WILL
 CONFORM TO THE PROVISIONS OF THIS CODE AND RELEVANT
 LAWS, ORDINANCES, RULES AND REGULATIONS, AS DETERMINED
 BY THE BUILDING OFFICIAL. THE TITLE SHEET STATES NEW
 MEZZANINE.
  
 3) SHEET S1:
 3A) COMPLIED.
  
 3B) COMPLIED
 3C) COMPLIED.
  
 4) SEMI-COMPLIED SEE COMMENTS BELOW.
 4A) COMPLIED.
  
 4B) COMPLIED.
  
 4C)(1) SEMI-COMPLIED, SHEET S-3 MEZZANINE STORAGE AREA,
 < THAN 5 OCCUPANTS 330 SF/ 300 = 2 OCCUPANTS VS SHEET
 S1 THE MEZZANINE IS SHOWN AS A MERCANTILE OCCUPANCY 330
 SF/60 =5.5 ALWAYS ROUND UP OR 6 OCCUPANTS REQUIRING
 VERTICAL ACCESSIBILITY. 2020 FBC-ACCESSIBILITY CODE
 SECTION 201.1.1.
 4C)(2) COMPLIED.
  
 4D) SHEET S3: SEMI COMPLIED. SEE COMMENT ABOVE.
  
 4E) (1) COMPLIED.
  
  
 4E)(2) 4TH REQUEST. SEMI-COMPLIED, STILL ISSUES, THE
 AREA BENEATH THE STAIRS TO BE USED AS STORAGE BOTH THE
 CEILING AND WALL HAVE TO BE 1-HOUR FIRE RATED BUT THERE
 IS A VENT-PASS THROUGH SEE SECTION 708.9 TRANSFER
 OPENINGS. THE SECOND ISSUE IS SHEET S1 STATES THE WALL
 TO BE 1-HOUR FIRE RATED BUT THE DOOR BENEATH THE STAIRS
 NOT RATED PER FBC-BUILD TABLE 716.5.
  
 4F-G) COMPLIED.
  
 5-7) COMPLIED.
  
 8) A TRANSMITTAL LETTER / NARRATIVE LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT
 REMARKS MAYBE MADE IN THE NEXT REVIEW CYCLE.
  
  
 MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM
 PART-TIME/ SEMI-RETIRED.
  
 IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET
 BACK INTO THE OFFICE CALL
 (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL.
 THANK YOU.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  