| 2022-12-14 16:52:40 | RE-ROOF RESIDENTIAL, SECOND BUILDING REVIEW COMMENTS |
| | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. |
| | PERMIT #22110836 |
| | 705 PALM BEACH LAKES BLVD |
| | |
| | 1- PROVIDE PRODUCT APPROVAL AS REQUIRED BY F.A.C. |
| | 61G20-3.001 FOR: |
| | |
| | A)OK. |
| | |
| | ORIGINAL COMMENT: |
| | B)ROOFING UNDERLAYMENT. NOTE: COORDINATE WITH ITEM #2 |
| | BELOW. |
| | |
| | RESPONSE: |
| | NOA 18-0919.12 SUBMITTED IS FOR MODIFIED BITUMEN ROOF |
| | SYSTEMS (FLAT ROOF ASSEMBLIES) NOT A SHINGLES |
| | UNDERLAYMENT. NEED TO SUBMIT PRODUCT APPROVAL FOR |
| | UNDERLAYMENT DESIGNED FOR SHINGLES UNDERLAYMENT. NOTE: |
| | COORDINATE WITH ITEM #2 BELOW. |
| | |
| | ORIGINAL COMMENT: |
| | 2- PROVIDE SPECIFICATIONS SHOWING HOW COMPLYING WITH |
| | THE NEW 2020 CODE REQUIREMENT FOR ROOFING UNDERLAYMENT. |
| | SEC. R905.1.1.1 FBC-RESIDENTIAL. |
| | NOTE: CLEARLY SPECIFY WHICH METHOD OF SEC. R905.1.1.1 |
| | FBC-RESIDENTIAL IS GOING TO BE USED. AND PROVIDE |
| | PRODUCT APPROVAL AS REQUIRED BY F.A.C. 61G20-3.001. |
| | |
| | RESPONSE: |
| | REPEAT COMMENT. NOT ADDRESSED. |
| | |
| | ORIGINAL COMMENT: |
| | 3- NEED TO SPECIFY THE MEAN ROOF HEIGHT, ROOF PITCH, |
| | ROOF AREAS (PITCHED AND FLAT AREAS) AS REQUIRED BY THE |
| | CITY POLICY FOR ALL ROOFING PERMITS. SEC. 107.2.1 CITY |
| | AMENDMENTS. |
| | NOTE: AN SKETCH SHOWING THE ROOF AREAS WILL HELP |
| | EXPEDITE YOUR PERMIT. |
| | |
| | RESPONSE: |
| | REPEAT COMMENT. NOT ADDRESSED. |
| | |
| | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY |
| | QUESTIONS REGARDING THESE COMMENTS, |