| Date |
Text |
| 2022-11-23 16:07:33 | 1ST REVIEW FBC-2020 PLUMBING | | | PERMIT- 22110693 | | | 11/23/2022 | | | | | | CODES IN EFFECT: | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET A4.22: SEC. 604.2 FBC ACC REQUIRES THE | | | CENTERLINE OF THE WATER CLOSET TO BE 16 INCHES MINIMUM | | | TO 18-INCHES MAXIMUM FROM THE SIDE WALL. THERE IS NO | | | EXCEPTION FOR PRIVATE BATHROOMS. BASED ON THE PLAN | | | NOTE, THE CENTERLINE OF THE WATER CLOSET WAS RELOCATED | | | TO 19-INCHES DUE TO THE BEAM OBSTRUCTION BELOW, HOWEVER | | | THE ROOM WIDTH DIMENSION OF 5???6??? INDICATES THERE IS | | | SUFFICIENT ROOM TO EITHER MOVE THE WALL INWARD OR FURR | | | IT OUT 1-INCH SO THAT THE CENTERLINE OF THE WATER | | | CLOSET WOULD BE IN COMPLIANCE. IT DOES NOT APPEAR THE | | | EXCEPTIONS UNDER SEC. 203.15 FBC ACC STRUCTURAL | | | IMPRACTICALLY ARE APPLICABLE TO THIS SITUATION. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|