| Date |
Text |
| 2022-12-20 16:04:17 | 1ST PLUMBING REVIEW |
| | |
| | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED |
| | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. |
| | |
| | 1. P-501 - DETAIL #13 - 2020 FPC 607.1.1 - HOT WATER |
| | DELIVERY MUST ALSO BE LIMITED BY A THERMOSTATIC MIXING |
| | DEVICE. A THERMOSTATIC MIXING DEVICE MUST BE ON THE HOT |
| | WATER LINE. THIS IS IN ADDITION TO THE REQUIREMENTS FOR |
| | TEMPERED WATER REQUIRED BY 607.1.2. |
| | |
| | 2. P-302 -- 2020 FEC C404.5.1 - MAXIMUM DISTANCE TO A |
| | PUBLIC LAVATORY FROM THE NEAREST SOURCE OF HEATED WATER |
| | SHALL BE LIMITED TO 2' ON 1/2" PIPE AND .5' ON 3/4" |
| | PIPE. PLEASE ADJUST THE DOMESTIC WATER ISOMETRIC TO |
| | INDICATE COMPLIANCE. (THE HOT WATER LOOP MUST LOOP DOWN |
| | TO WITHIN 2' OF THE PUBLIC LAVS). |
| | |
| | 3. P-503 -- 2017 WPB AMENDS 107.2.1 - MISSING FROM THE |
| | PLUMBING KITCHEN EQUIPMENT SCHEDULE ARE SEVERAL OF THE |
| | REFERENCES ON THE SANITARY FLOOR PLAN. EXAMPLES FROM |
| | THE BAR AREA P-317.1;P-319.1;P-316.1;P-310.1. PLEASE |
| | CLARIFY. |
| | A) PAGE P-200 (BOH SEMI-OPEN AREA) - P220.1 IS LISTED |
| | AS A "DECK BROILER" AND IS POINTING TO A THE HAND SINK |
| | |
| | |
| | 4. 2020 FPC 1003.3.1 - BAR AREA HAND SINK DISCHARGES TO |
| | THE GREASE WASTE AND SHOULD NOT. ONLY FIXTURES DESIGNED |
| | TO RECEIVE FATS, OILS, AND GREASE WASTES SHALL |
| | DISCHARGE TO THE INTERCEPTOR. ALL OTHERS SHALL BE |
| | DIRECTED TO THE SANITARY, INCLUDING CONDENSATES FROM |
| | COOLING EQUIPMENT. ONLY A/C (ROOM CONDITIONERS) |
| | CONDENSATES NEED DIRECTED TO STORM. FEEL FREE TO CALL |
| | TO CLARIFY THIS COMMENT. |
| | |
| | |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM. |
| | |
| | |
| | RYAN W. BROWN |
| | CHIEF PLUMBING INSPECTOR |
| | OFFICE: 561-805-6692 |
| | CELL: 561-517-4293 |
| | EMAIL: [email protected] |
| | |
| | |
| | V7 FPC - 2020 FLORIDA PLUMBING CODE |
| | V7 FGC - 2020 FLORIDA FUEL GAS |
| | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE |
| | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE |
| | V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE |
| | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION |
| | 2021 F.S. - 2021 FLORIDA STATUTES |
| | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE |
| | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE |
| | FBC CHAPTER 1 |
| | |