Date Text
2022-12-17 10:11:052ND NFIP REVIEW
 CORRECTIONS REQUIRED
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 INSPECTOR BN4338
 BUILDING OFFICIAL BU1635
 ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935
 DEVELOPMENT SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 CITY ORDINANCE NO. 4658-16 AND NO. 4729-17
 FEMA DESK REFERENCE P 758
 FBC R322 FLOOD-RESISTANT CONSTRUCTION
  
 NOTICE: THIS PROJECT IS LOCATED IN A SPECIAL FLOOD
 HAZARD AREA (SFHA). THE FLOOD ZONE DESIGNATIONS FOR
 THIS SITE ARE AE 6 AND AE 7 WITH A BASE FLOOD ELEVATION
 (BFE) OF 7'0" NAVD.
 THE CITY OF WEST PALM BEACH (THROUGH ORDINANCE NO.
 4729-17) REQUIRES AN ADDITIONAL 24 INCHES OF FREEBOARD.
 THE DESIGN FLOOD ELEVATION (DFE) SHALL BE AT OR ABOVE
 9'0" NAVD.
  
 CITY OF WEST PALM BEACH, FLORIDA ORDINANCE NO. 4729-17
 SECTION 4: THE CODE OF ORDINANCES IS HEREBY AMENDED AT
 CHAPTER 18, BUILDINGS AND BUILDING REGULATIONS, ARTICLE
 II, BUILDING CODE, TO ADD SECTION 18-33, TECHNICAL
 AMENDMENTS TO FLORIDA BUILDING CODE, RESIDENTIAL, WHICH
 SHALL READ AS FOLLOWS:
 SEC. 18-33 - TECHNICAL AMENDMENTS TO FLORIDA BUILDING
 CODE, RESIDENTIAL.
 R322.2.1 ELEVATION REQUIREMENTS.
 BUILDINGS AND STRUCTURES IN FLOOD HAZARD AREAS NOT
 DESIGNATED AS COASTAL A ZONES SHALL HAVE THE LOWEST
 FLOORS ELEVATED TO OR ABOVE THE BASE FLOOD ELEVATION
 PLUS ONE FOOT, OR THE DESIGN FLOOD ELEVATION, WHICHEVER
 IS HIGHER. (PLUS TWO FEET PER CITY ORDINANCE 4729-17).
  
 CONSTRUCTION DRAWING ELEVATION CERTIFICATE (EC)
 SUBMITTED FOR REVIEW:
 ADDRESS THE FOLLOWING COMMENTS:
  
 NOTICE:
 PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED
 SATISFACTORILY ARE MARKED AS CORRECTED OR REMOVED.
 PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED
 SATISFACTORILY MAY HAVE ADDITIONAL COMMENTS IN
 PARENTHESES. ANY NEW COMMENT WILL BE LISTED AFTER
 PREVIOUS COMMENTS.
  
  
 1.
  
 2. LINES A9 A THRU A9 D. DATA MISSING.
 (LINE A9A COVER PAGE STATES GARAGE IS 857SF)
 (LINES A9B & A9C DATA MISSING)
 (LINE A9D EOR STATES FLOOD OPENINGS WILL BE ENGINEERED
 OPENINS)
  
  
 3.
  
 4. LINE C2A) LOWEST FLOOR.
 PER R322.1.5LOWEST FLOOR.
 (LOWEST FLOOR IS 6.5 ENTRY AREA OFF OF GARAGE)
  
 5. LINE C2B) MISSING DATA.
 (NEXT HIGHEST FLOOR IS 7.75' STORAGE)
  
 6. C2D) MISSING DATA.
 (GARAGE FF EL. IS 6.5;)
  
 7.
  
 8. SECTION D COMMENTS: MISSING COMMENTS: USE THIS SPACE
 TO DESCRIBE TYPE OF EQUIPMENT IN C2E) AND IT'S
 LOCATION, ENGINEERED FLOOD OPENINGS, IF PRESENT AND
 OTHER RELEVANT INFORMATION NOT SPECIFIED ESLSEWHWERE ON
 THE CERTIFICATE.
 (STATE MODEL NUMBER OF SNART VENTS. INCLUDE SF
 COVERGAGE OF EACH VENT)
  
 NEW COMMENT:
  
 9. EC MISSING PAGES 5 & 6. FEMA REQUIRES A COMPLETE
 CERTIFICATE.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
  
  