| Date |
Text |
| 2022-11-22 10:49:42 | 1ST NFIP PLAN REVIEW |
| | CORRECTIONS REQUIRED |
| | |
| | CHRISTOPHER S. THROOP, C.B.O., CFM |
| | PLANS EXAMINER II PX3169/SFP306 |
| | INSPECTOR BN4338 |
| | BUILDING OFFICIAL BU1635 |
| | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | CITY OF WEST PALM BEACH |
| | (561) 805-6726 |
| | [email protected] |
| | |
| | |
| | CODES IN EFFECT: |
| | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST |
| | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, |
| | CHAPTER 1 ADMINISTRATION |
| | CITY ORDINANCE NO. 4658-16 AND NO. 4729-17 |
| | FEMA DESK REFERENCE P 758 |
| | FBC R322 FLOOD-RESISTANT CONSTRUCTION |
| | |
| | NOTICE: THIS PROJECT IS LOCATED IN A SPECIAL FLOOD |
| | HAZARD AREA (SFHA). THE FLOOD ZONE DESIGNATIONS FOR |
| | THIS SITE ARE AE 6 AND AE 7 WITH A BASE FLOOD ELEVATION |
| | (BFE) OF 7'0" NAVD. |
| | THE CITY OF WEST PALM BEACH (THROUGH ORDINANCE NO. |
| | 4729-17) REQUIRES AN ADDITIONAL 24 INCHES OF FREEBOARD. |
| | THE DESIGN FLOOD ELEVATION (DFE) SHALL BE AT OR ABOVE |
| | 9'0" NAVD. |
| | |
| | CITY OF WEST PALM BEACH, FLORIDA ORDINANCE NO. 4729-17 |
| | SECTION 4: THE CODE OF ORDINANCES IS HEREBY AMENDED AT |
| | CHAPTER 18, BUILDINGS AND BUILDING REGULATIONS, ARTICLE |
| | II, BUILDING CODE, TO ADD SECTION 18-33, TECHNICAL |
| | AMENDMENTS TO FLORIDA BUILDING CODE, RESIDENTIAL, WHICH |
| | SHALL READ AS FOLLOWS: |
| | SEC. 18-33 - TECHNICAL AMENDMENTS TO FLORIDA BUILDING |
| | CODE, RESIDENTIAL. |
| | R322.2.1 ELEVATION REQUIREMENTS. |
| | BUILDINGS AND STRUCTURES IN FLOOD HAZARD AREAS NOT |
| | DESIGNATED AS COASTAL A ZONES SHALL HAVE THE LOWEST |
| | FLOORS ELEVATED TO OR ABOVE THE BASE FLOOD ELEVATION |
| | PLUS ONE FOOT, OR THE DESIGN FLOOD ELEVATION, WHICHEVER |
| | IS HIGHER. (PLUS TWO FEET PER CITY ORDINANCE 4729-17). |
| | |
| | CONSTRUCTION DRAWING ELEVATION CERTIFICATE (EC) |
| | SUBMITTED FOR REVIEW: |
| | ADDRESS THE FOLLOWING COMMENTS: |
| | |
| | 1. LINE A7. BUILDING DIAGRAM SHOULD BE 1B PER EC |
| | INSTRUCTIONS. |
| | |
| | 2. LINES A9 A THRU A9 D. DATA MISSING. |
| | |
| | 3. LINE B9 THE BUILDING IS LOCATED IN MORE THAN ONE |
| | FLOOD ZONE, LIST ALL BFE'S: BASE FLOOD ELEVATIONS ARE 6 |
| | AND 7. |
| | |
| | 4. LINE C2A) LOWEST FLOOR. |
| | PER R322.1.5LOWEST FLOOR. |
| | |
| | 5. LINE C2B) MISSING DATA. |
| | |
| | 6. C2D) MISSING DATA. |
| | |
| | 7. LINE C2E) MISSING DATA. |
| | |
| | 8. SECTION D COMMENTS: MISSING COMMENTS: USE THIS SPACE |
| | TO DESCRIBE TYPE OF EQUIPMENT IN C2E) AND IT'S |
| | LOCATION, ENGINEERED FLOOD OPENINGS, IF PRESENT AND |
| | OTHER RELEVANT INFORMATION NOT SPECIFIED ESLSEWHWERE ON |
| | THE CERTIFICATE. |
| | |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| | |
| | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. |
| | |
| | |
| | |
| | |
| | |