2022-11-22 10:49:421ST NFIP PLAN REVIEW
 CORRECTIONS REQUIRED
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 INSPECTOR BN4338
 BUILDING OFFICIAL BU1635
 ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935
 DEVELOPMENT SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 CITY ORDINANCE NO. 4658-16 AND NO. 4729-17
 FEMA DESK REFERENCE P 758
 FBC R322 FLOOD-RESISTANT CONSTRUCTION
  
 NOTICE: THIS PROJECT IS LOCATED IN A SPECIAL FLOOD
 HAZARD AREA (SFHA). THE FLOOD ZONE DESIGNATIONS FOR
 THIS SITE ARE AE 6 AND AE 7 WITH A BASE FLOOD ELEVATION
 (BFE) OF 7'0" NAVD.
 THE CITY OF WEST PALM BEACH (THROUGH ORDINANCE NO.
 4729-17) REQUIRES AN ADDITIONAL 24 INCHES OF FREEBOARD.
 THE DESIGN FLOOD ELEVATION (DFE) SHALL BE AT OR ABOVE
 9'0" NAVD.
  
 CITY OF WEST PALM BEACH, FLORIDA ORDINANCE NO. 4729-17
 SECTION 4: THE CODE OF ORDINANCES IS HEREBY AMENDED AT
 CHAPTER 18, BUILDINGS AND BUILDING REGULATIONS, ARTICLE
 II, BUILDING CODE, TO ADD SECTION 18-33, TECHNICAL
 AMENDMENTS TO FLORIDA BUILDING CODE, RESIDENTIAL, WHICH
 SHALL READ AS FOLLOWS:
 SEC. 18-33 - TECHNICAL AMENDMENTS TO FLORIDA BUILDING
 CODE, RESIDENTIAL.
 R322.2.1 ELEVATION REQUIREMENTS.
 BUILDINGS AND STRUCTURES IN FLOOD HAZARD AREAS NOT
 DESIGNATED AS COASTAL A ZONES SHALL HAVE THE LOWEST
 FLOORS ELEVATED TO OR ABOVE THE BASE FLOOD ELEVATION
 PLUS ONE FOOT, OR THE DESIGN FLOOD ELEVATION, WHICHEVER
 IS HIGHER. (PLUS TWO FEET PER CITY ORDINANCE 4729-17).
  
 CONSTRUCTION DRAWING ELEVATION CERTIFICATE (EC)
 SUBMITTED FOR REVIEW:
 ADDRESS THE FOLLOWING COMMENTS:
  
 1. LINE A7. BUILDING DIAGRAM SHOULD BE 1B PER EC
 INSTRUCTIONS.
  
 2. LINES A9 A THRU A9 D. DATA MISSING.
  
 3. LINE B9 THE BUILDING IS LOCATED IN MORE THAN ONE
 FLOOD ZONE, LIST ALL BFE'S: BASE FLOOD ELEVATIONS ARE 6
 AND 7.
  
 4. LINE C2A) LOWEST FLOOR.
 PER R322.1.5LOWEST FLOOR.
  
 5. LINE C2B) MISSING DATA.
  
 6. C2D) MISSING DATA.
  
 7. LINE C2E) MISSING DATA.
  
 8. SECTION D COMMENTS: MISSING COMMENTS: USE THIS SPACE
 TO DESCRIBE TYPE OF EQUIPMENT IN C2E) AND IT'S
 LOCATION, ENGINEERED FLOOD OPENINGS, IF PRESENT AND
 OTHER RELEVANT INFORMATION NOT SPECIFIED ESLSEWHWERE ON
 THE CERTIFICATE.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
  
  
  
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved