| 2022-11-14 08:32:03 | W. P. B. BUILDING DEPARTMENT HAS | | | ALL (3) REQUIRED TEST ON FILE AT CITY HALL | | | ON (F) DRIVE FLOOR UNDERLAYMENTS FOR | | | PERMIT: 22040998: | | | WHISPER MAT CS/ TILE OR MARBLE | | | IIC = 50 DB / 6 INCH SLAB P. T. / NO DROPPED CEILING / | | | ASTM E-492 | | | STC = 55 DB / 6 INCH SLAB P. T./ NO DROPPED / CEILING | | | ASTM E-90 | | | FLAME= 0 ASTM-E84 | | | SMOKE= 35 ASTM E-84 | | | J. WITMER BUILD PLAN REVIEW 11/14/2022 | | | | | | |
|