2023-01-09 15:03:132ND REVIEW FMC
 PERMIT: 22101347
  
 CODES IN EFFECT: 2020
  
 FBC- FLORIDA BUILDING CODE
 FMC- FLORIDA MECHANICAL CODE
 FEC- FLORIDA ENERGY CONSERVATION
 FGC- FLORIDA FUEL GAS
 FEX- FLORIDA EXISTING BUILDING CODE
 FRC- FLORIDA RESIDENTIAL BUILDING CODE
 F.S.- FLORIDA STATUTES
 FAC- FLORIDA ACCESSIBILITY CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PROVIDE A COMPLETE SCOPE OF WORK FOR THIS TENANT
 SPACE INCLUDING THE PREVIOUS LEGAL OCCUPANCY AND USE
 AND THE PROPOSED OCCUPANCY AND USE. PROVIDE A COMPLETE
 SET OF PLANS FOR THIS NEW RESTAURANT INCLUDING ALL
 TRADES. FBC 107.3.5
  
 2) THIS IS A NEW INSTALLATION FOR THIS HOOD, GREASE
 DUCT AND MAKE-UP AIR. WHY IS THIS HOOD BEING INSTALLED?
 WHAT TYPE OF APPLIANCES ARE TO BE USED UNDER THIS NEW
 HOOD. FBC 107.3.5
  
 3) PLEASE SHOW THE EXHAUST TERMINATION LOCATION WILL
 MEET THE CLEARANCES IN FMC 506.3.13.3
  
 506.3.13.3 TERMINATION LOCATION. EXHAUST OUTLETS SHALL
 BE LOCATED NOT LESS THAN 10 FEET (3048 MM) HORIZONTALLY
 FROM PARTS OF THE SAME OR CONTIGUOUS BUILDINGS,
 ADJACENT BUILDINGS AND ADJACENT PROPERTY LINES AND
 SHALL BE
 LOCATED NOT LESS THAN 10 FEET (3048 MM) ABOVE THE
 ADJOINING GRADE LEVEL. EXHAUST OUTLETS SHALL BE LOCATED
 NOT LESS THAN 10 FEET (3048 MM) HORIZONTALLY FROM OR
 NOT LESS THAN 3 FEET (914 MM) ABOVE AIR INTAKE OPENINGS
 INTO ANY BUILDING.
  
 4) PLEASE SHOW THAT ANY EQUIPMENT PLACED WITHIN 10 FOOT
 OF THE ROOFS EDGE WILL HAVE GUARD PROTECTION BASED ON
 FMC 304.11
  
 5) PROVIDE THE AIR BALANCE REPORT FOR THIS TENANT
 SPACE. FMC 508.1.2
  
 6) PLEASE SHOW THAT THE MAKE-UP AIR TEMPERATURE MEETS
 THE 10 DEGREE REQUIREMENT OF FMC 508.1.1
  
 7) PROVIDE CALCULATIONS THAT THE MECHANICAL SYSTEM IS
 DESIGNED FOR THE LOAD OF THIS NEW RESTAURANT. FMC 312.1
  
 8) PROVIDE THE OUTDOOR AIR CALCULATIONS FOR THIS
 RESTAURANT. FMC 403.3.1.1
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  