| 2022-12-07 12:47:20 | 1ST BUILDING REVIEW |
| | RESULTS: CORRECTIONS NEEDED |
| | |
| | CHRISTOPHER S. THROOP, CBO, BN, PX, CFM |
| | PLANS EXAMINER II |
| | CITY OF WEST PALM BEACH |
| | (561) 805-6726 |
| | [email protected] |
| | |
| | CODES IN EFFECT: |
| | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST |
| | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, |
| | CHAPTER 1 ADMINISTRATION |
| | NFPA 70 2017 EDITION NEC 2017 |
| | |
| | ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT: |
| | |
| | NOTICE: A FEMA ELEVATION CERTIFICATE (EC) WAS SUBMITTED |
| | FOR REVIEW. THIS PROPERTY IS NOT LOCATED IN A SPECIAL |
| | FLOOD HAZARD AREA (SFHA). THE CITY DOES NOT REVIEW EC'S |
| | FOR PROPERTIES THAT ARE NOT LOCATED IN A SFHA. |
| | |
| | 1. N/A |
| | |
| | 2. PROVIDE LOCATION OF ATTIC ACCESS PER R807.1.7. |
| | R807.1.7 BUILDINGS WITH COMBUSTIBLE CEILING OR ROOF |
| | CONSTRUCTION SHALL HAVE AN ATTIC ACCESS OPENING TO |
| | ATTIC AREAS THAT HAVE A VERTICAL HEIGHT OF 30 INCHES |
| | (762 MM) OR GREATER OVER AN AREA OF NOT LESS THAN 30 |
| | SQUARE FEET (2.8 M2). |
| | |
| | 3.PROVIDE A FLASHING DETAIL FOR WINDOWS AND EXT. DOORS |
| | PER R703.4 |
| | EXTERIOR WINDOW AND DOOR OPENINGS. FLASHING AT EXTERIOR |
| | WINDOW AND DOOR OPENINGS SHALL EXTEND TO THE SURFACE OF |
| | THE EXTERIOR WALL FINISH OR TO THE WATER-RESISTIVE |
| | BARRIER COMPLYING WITH SECTION 703.2 FOR SUBSEQUENT |
| | DRAINAGE. |
| | |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| | |
| | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. |
| | |
| | |