2023-05-16 16:44:49THE FOLLOWING COMMENTS WERE NOT ADDRESSED:
 1. STALL PAINTING DETAIL NEEDS TO BE PROVIDED AS A
 DRAWING TO MEET REQUIREMENTS AS PER SEC. 94-485.
  
 2. ALL STANDARD PARKING SPACES SHALL BE AT LEAST EIGHT
 FEET SIX INCHES IN WIDTH AND 18 FEET IN LENGTH. SOME
 DIMENSIONS ARE NOT LEGIBLE AND STANDARD SPACES SEEM TO
 BE EIGHT FEET FIVE INCHES IN WIDTH WHICH DO NOT MEET
 THE REQUIREMENT.
  
 PLEASE EXPLAIN HOW YOU ARE MEETING THE FOLLOWING
 REQUIREMENTS FOR THE PARKING SPACE FOR THE DISABLE:
 A. ALL SPACES SHALL HAVE ACCESS TO A CURB RAMP OR CURB
 CUT, WHEN NECESSARY, TO ALLOW ENTRANCE TO THE BUILDING
 SERVED. SPACES SHALL BE LOCATED SO THAT USERS ARE NOT
 COMPELLED TO WALK OR OTHERWISE MOVE BEHIND PARKED
 VEHICLES, EXCLUDING OTHER VEHICLES PARKED IN ADJACENT
 PARKING SPACES FOR THE DISABLED.
 B. PARKING SPACES FOR DISABLE WILL ALSO NEED TO HAVE
 THE CITY???S STALL PAINTING DETAIL.
 C. EACH DISABLED PARKING SPACE SHALL BE PROMINENTLY
 OUTLINED WITH A PERMANENT SIGN OF COLOR AND DESIGN
 APPROVED BY THE STATE DEPARTMENT OF TRANSPORTATION. THE
 SIGN SHALL CONTAIN THE INTERNATIONALLY ACCEPTED
 WHEELCHAIR SYMBOL AND THE CAPTION "PARKING BY DISABLED
 PERMIT ONLY.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU REQUIRED FUTHRE
 CLARIFICATION.
  
 CLAUDIA D. IBAVEN
 CITY URBAN DESIGNER / ZONING AND PLANNING
 [email protected]
 561-822-1402
  