| Date |
Text |
| 2022-11-16 19:18:24 | RESIDENTIAL (R3) RE-ROOF BUILDING REVIEW COMMENTS |
| | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. |
| | PERMIT #22101219 |
| | 3311 POINSETTIA AVE |
| | |
| | 1- POLYGLASS POLYSTICK UNDERLAYMENT (NOA 21-1217.02) |
| | DOESN'T LIST THE TILE BOND ROOF TILE ADHESIVE (NOA |
| | 21-1006.03) AS APPROVED ADHESIVE TO BE USED WITH THIS |
| | UNDERLAYMENT. PROVIDE UNDERLAYMENT LISTING THE TILE |
| | BOND ADHESIVE. |
| | FAC 61G20.3.001 |
| | |
| | 2- HIP AND RIDGE INSTALLATION: PROVIDE COMPLETE DETAILS |
| | AND SPECIFICATIONS FOR HIP AND RIDGE INSTALLATION AS |
| | REQUIRED BY SEC. R905.3.7.1 FBC-RESIDENTIAL. SPECIFY |
| | STRUCTURAL SUPPORT MATERIAL AND PROVIDE PRODUCT |
| | APPROVAL AS REQUIRED. |
| | NOTE: CLEARLY MARK ON PRODUCT APPROVAL ATTACHMENT |
| | METHOD. |
| | |
| | 3- ROOF TILE NOA 22-0714.17 AND ROOF TILE ADHESIVE |
| | SUBMITTED: CLEARLY MARK ADHESIVE PADDY SIZE TO BE USED |
| | AS REQUIRED BY CITY POLICY FOR ALL ROOFING PERMITS TO |
| | VERIFY COMPLIANCE WITH THE DESIGN PRESSURES OF SEC |
| | R301.2.1 FBC-RESIDENTIAL. |
| | |
| | 4- RAS 117 CALCULATIONS NEED THE ORIGINAL SEAL AND |
| | SIGNATURE OF THE ENGINEER AS REQUIRED BY CHAPTER 471 |
| | FLORIDA STATUTES WHEN SUBMITTING DOCUMENTS/PLANS FOR |
| | PUBLIC RECORDS. |
| | NOTE: SUBMIT CALCULATIONS ELECTRONICALLY WITH |
| | ENGINEER'S VERIFIABLE DIGITAL SIGNATURE OR PROVIDE HARD |
| | COPY WITH ORIGINAL SEAL/SIGNATURE. |
| | |
| | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY |
| | QUESTIONS REGARDING THESE COMMENTS, |
| | JULIO GOMEZ |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | BUILDING DIVISION |
| | (561)805-6712 |
| | [email protected] |
| | |