Plan Review Notes
Plan Review Notes For Permit 22101089
Permit Number 22101089
Review Stop B
Sequence Number 1
Notes
Date Text
2022-11-18 13:33:35CANOPY
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) PLEASE SHOW THE DIMENSION FROM THE GROUND TO THE
 BOTTOM OF THE AWNING FRAME - FBC 3105.3.1.1
 FABRIC AWNINGS AND FABRIC-COVERED FRAMES LOCATED OVER
 PUBLIC PROPERTY OR IN AREAS ACCESSIBLE TO THE GENERAL
 PUBLIC SHALL BE CONSTRUCTED SO THAT NO RIGID PART OF
 SUCH FABRIC AWNINGS OR FABRIC-COVERED FRAMES SHALL BE
 LESS THAN 7 FEET 6 INCHES (2286 MM) FROM THE GRADE
 DIRECTLY BELOW, AND NO PART OF THE CLOTH DROP SHALL BE
 LESS THAN 7 FEET (2134 MM).
  
 2) PLEASE SHOW THE LOCATION OF THE AWNING TO COMPLY
 WITH - FBC 3105.3.1.2
 A FIXED FABRIC AWNING OR FABRIC-COVERED FRAME SHALL NOT
 EXTEND OVER PUBLIC PROPERTY MORE THAN TWO-THIRDS THE
 DISTANCE FROM THE PROPERTY LINE TO THE NEAREST CURB
 LINE IN FRONT OF THE BUILDING SITE AS MEASURED FROM THE
 EXTERIOR FACE OF THE BUILDING, NOR SHALL ANY PORTION BE
 CLOSER THAN 18 INCHES (457 MM) TO THE CURB LINE.
  
 3) SHOW THE LOCATION DIMENSIONS OF THE AWNINGS FROM THE
 PROPERTY LINES AND CURBS BY DRAWING THEM ON THE SURVEY
 IN THE ACTUAL PROPOSED LOCATIONS.
  
 4) DRAWINGS NEED TO BE ELECTRONICALLY/DIGITALLY SIGNED
 BY THE DESIGNER, SIGNED AND SEALED DRAWINGS IN
 PROJECTDOX NEED TO BE DIGITALLY/ELECTRONICALLY SIGNED
 TO BE USED IN ELECTRONIC PLAN REVIEW. (A
 CERTIFICATE-BASED DIGITAL SIGNATURE (OFTEN JUST CALLED
 A DIGITAL SIGNATURE) IS A SPECIFIC TYPE OF
 E-SIGNATURE).
  
  
  
  
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved