| Plan Review Notes For Permit 22100849 |
| Permit Number |
22100849 |
|
| Review Stop |
B |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2022-12-20 15:18:31 | BUILDING PROVISO: | | | 2020 FBC-B 1210.2.2. WALLS & PARTITIONS. THIS COMMENT | | | IS A RESULT OF THE BUILDING OFFICIAL INTERPRETATION ON | | | 06/2020. IN BATHROOMS, RESTROOMS & SERVICE SINK AREAS | | | EPOXY PAINT IS NO LONGER CONSIDERED A SMOOTH HARD, | | | NON-ABSORBENT SURFACE. | | | 2020 FBC-B 2509.2 BASE FOR TILE. MATERIALS USED AS A | | | BASE FOR WALL TILE IN TUB AND SHOWER AREAS AND WALLS | | | AND CEILING PANELS IN SHOWER AREAS SHALL BE OF | | | MATERIALS LISTED IN TABLE 2509.2 AND INSTALLED IN | | | ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. WATER | | | RESISTANT GYPSUM (MR BOARD) SHALL NOT BE USED FOR | | | SHOWER & TUB ENCLOSURES BUT CAN BE USED FOR BACKING | | | BOARD FOR A BASE FOR TILE IN WATER CLOSET COMPARTMENT | | | WALLS WHEN INSTALLED IN ACCORDANCE WITH GA-216 OR ASTM | | | C840 AND THE MANUFACTURE'S RECOMMENDATIONS. | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | |
|