Plan Review Notes
Plan Review Notes For Permit 22100595
Permit Number 22100595
Review Stop B
Sequence Number 2
Notes
Date Text
2023-02-13 14:09:37ROOFING
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) PLEASE PROVIDE THE DETAILS FOR THE ROOF TO WALL
 CONNECTIONS - FBC R908.8 WHEN A ROOF COVERING ON AN
 EXISTING STRUCTURE WITH A SAWN LUMBER, WOOD PLANK OR
 WOOD STRUCTURAL PANEL ROOF DECK IS REMOVED AND REPLACED
 ON A BUILDING THAT IS LOCATED IN THE WIND-BORNE DEBRIS
 REGION AS DEFINED IN THE FLORIDA BUILDING CODE,
 BUILDING AND THAT HAS AN INSURED VALUE OF $300,000 OR
 MORE OR, IF THE BUILDING IS UNINSURED OR FOR WHICH
 DOCUMENTATION OF INSURED VALUE IS NOT PRESENTED, HAS A
 JUST VALUATION FOR THE STRUCTURE FOR PURPOSES OF AD
 VALOREM TAXATION OF $300,000 OR MORE:
  
 (A)ROOF TO WALL CONNECTIONS SHALL BE IMPROVED AS
 REQUIRED BY SECTION R908.8.1.
  
 (B)MANDATED RETROFITS OF THE ROOF-TO-WALL CONNECTION
 SHALL NOT BE REQUIRED BEYOND A 15 PERCENT INCREASE IN
 THE COST OF RE-ROOFING.
  
 2) THE PROVIDED ADDITIONAL ROOFING ATTACHMENT FROM
 "FORENSIC ENGINEERING CONSULTANTS" NEEDS TO BE
 DIGITALLY SIGNED BY THE ENGINEER - SIGNED AND SEALED
 DRAWINGS IN PROJECTDOX NEED TO BE
 DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN
 ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL
 SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A
 SPECIFIC TYPE OF E-SIGNATURE).