| Plan Review Notes For Permit 22100591 |
| Permit Number |
22100591 |
|
| Review Stop |
E |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2022-11-02 11:39:56 | FLORIDA BUILDING CODE 2020 7TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | | NFPA 70 2017 EDITION | | | | | | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | 406.4(D)ARC-FAULT CIRCUIT-INTERRUPTER PROTECTION. | | | | | | WHERE A RECEPTACLE OUTLET IS LOCATED IN ANY AREAS | | | SPECIFIED IN 210.12(A) OR (B), A REPLACEMENT RECEPTACLE | | | AT THIS OUTLET SHALL BE ONE OF THE FOLLOWING: | | | | | | (1) A LISTED OUTLET BRANCH-CIRCUIT TYPE ARC-FAULT | | | CIRCUIT-INTERRUPTER RECEPTACLE | | | | | | (2) A RECEPTACLE PROTECTED BY A LISTED OUTLET | | | BRANCH-CIRCUIT TYPE ARC-FAULT CIRCUIT-INTERRUPTER TYPE | | | RECEPTACLE | | | | | | (3) A RECEPTACLE PROTECTED BY A LISTED COMBINATION TYPE | | | ARC-FAULT CIRCUIT-INTERRUPTER TYPE CIRCUIT BREAKER | | | | | | PLEASE SHOW LOCATION OF ALL SWITCHES AND RECEPTACLES TO | | | BE REPLACED. |
|