Plan Review Notes
Plan Review Notes For Permit 22100334
Permit Number 22100334
Review Stop B
Sequence Number 2
Notes
Date Text
2022-11-02 17:59:40RESIDENTIAL R(3) REVISION, SECOND BUILDING REVIEW
 COMMENTS
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 REVISION #22100334
 6205 WASHINGTON RD
  
 ORIGINAL BUILDING PROVISO:
 1- OK.
 2- OK.
 3- OK.
 4- OK.
 5- OK.
 6- OK.
 7- OK.
 8- OK.
  
 9- PROVIDE PRODUCT APPROVAL FOR:
  
 ORIGINAL COMMENT:
 A)NEW DOOR ON FLORIDA PRODUCT APPROVAL FL21133.31
 SUBMITTED DOESN'T MEET THE DESIGN PRESSURES CALCULATED
 BY THE ENGINEER OF RECORD. NEED PRODUCT APPROVAL THAT
 MEETS OR EXCEEDS THE CALCULATED DESIGN PRESSURES.
  
 RESPONSE:
 NEW PRODUCT APPROVAL NOT SUBMITTED FOR REVIEW.
  
 ORIGINAL COMMENT:
 B)WINDOW MULLIONS (NOTE: NEED TO SPECIFY MULLION SIZE
 TO VERIFY PRESSURES.
  
 RESPONSE:
 NEW PRODUCT APPROVAL NOT SUBMITTED FOR REVIEW.
  
 ORIGINAL COMMENT:
 10- ENGINEER OF RECORD TO APPROVE ABOVE PRODUCT
 APPROVALS.
  
  
 11- REVISE ENERGY CALCULATIONS SUBMITTED:
 (NOTE: REVISED ENERGY CALCULATIONS WERE NOT SUBMITTED
 FOR REVIEW)
  
 ORIGINAL COMMENTS:
 A)OK.
 B) OK.
  
 ORIGINAL COMMENT:
 C)DOORS ORIENTATION DOESN'T MATCH PLANS.
  
 RESPONSE:
 ORIENTATION OF DOORS WAS REVISED BUT BASED ON EXTERIOR
 ELEVATIONS THE MASTER BEDROOM DOOR IS A GLAZED DOOR.
 THIS DOOR NEEDS TO BE UNDER THE GLAZING AREA. REVISE AS
 REQUIRED. SEC. R405.5.3.3 FBC-ENERGY CONSERVATION.
  
 ORIGINAL COMMENT:
 D)REVISE WINDOWS INFORMATION ON PAGE 4. WINDOWS
 ORIENTATION, MATERIAL, AND OVERHANG DEPTH AND
 SEPARATION TO MATCH PLANS.
  
 RESPONSE:
 WINDOWS OVERHANG DEPTH DOESN'T MATCH PLANS. SEC.
 R405.5.3.3 FBC-ENERGY CONSERVATION. SEE ELEVATIONS.
 NOTE: THERE IS A NOTE FOR AWNING ON THE FLOOR PLAN BUT
 AWNINGS SHALL NOT BE CONSIDERED AS OVERHANGS.
  
 ORIGINAL COMMENT:
 E)BUILDER TO COMPLETE THE ENERGY PERFORMANCE LEVEL
 (EPL) DISPLAY CARD.
  
 RESPONSE:
 NOT ADDRESSED.
  
 F)OK.
  
 NEW COMMENT:
 G) ENERGY CALCULATIONS SUBMITTED WERE NOT SIGNED BY THE
 ENGINEER OF RECORD.
 THE BUILDING'S OWNER, THE OWNER'S ARCHITECT, OR OTHER
 AUTHORIZED AGENT LEGALLY DESIGNATED BY THE OWNER SHALL
 CERTIFY AT THE OWNER/AGENT LINE AT THE BOTTOM OF FORM
 THAT THE BUILDING IS IN COMPLIANCE WITH THE CODE, AS
 PER SECTION 553.907, FLORIDA STATUTES, PRIOR TO
 RECEIVING THE PERMIT TO BEGIN CONSTRUCTION OR
 RENOVATION AS REQUIRED BY SECTION R103.1.1.2 FBC-ENERGY
 CONSERVATION.
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF WHERE AND
 HOW THE COMMENT WAS ADDRESSED WILL HELP TO EXPEDITE THE
 REVIEW PROCESS. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  
  