| Date |
Text |
| 2022-12-09 16:18:38 | NEW METAL BUILDING |
| | REVIEWED BY ROGER MCPHERSON |
| | 561-805-6716 |
| | [email protected] |
| | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 |
| | AMENDMENT |
| | |
| | CORRECTIONS NEEDED - |
| | |
| | 1) PLEASE SHOW WHAT THE BUILDING WILL BE USED FOR - FBC |
| | 302.1 OCCUPANCY CLASSIFICATION. |
| | OCCUPANCY CLASSIFICATION IS THE FORMAL DESIGNATION OF |
| | THE PRIMARY PURPOSE OF THE BUILDING, STRUCTURE OR |
| | PORTION THEREOF. STRUCTURES SHALL BE CLASSIFIED INTO |
| | ONE OR MORE OF THE OCCUPANCY GROUPS LISTED IN THIS |
| | SECTION BASED ON THE NATURE OF THE HAZARDS AND RISKS TO |
| | BUILDING OCCUPANTS GENERALLY ASSOCIATED WITH THE |
| | INTENDED PURPOSE OF THE BUILDING OR STRUCTURE. |
| | |
| | 2) PLEASE PROVIDE A SITE PLAN SHOWING THE FOLLOWING |
| | INFORMATION FBC WPB 107.2.5 SITE PLAN. THE CONSTRUCTION |
| | DOCUMENTS SUBMITTED WITH THE APPLICATION FOR PERMIT |
| | SHALL BE ACCOMPANIED BY A SITE PLAN SHOWING TO SCALE |
| | THE SIZE AND LOCATION OF NEW CONSTRUCTION AND EXISTING |
| | STRUCTURES ON THE SITE, DISTANCES FROM LOT LINES, THE |
| | ESTABLISHED STREET GRADES AND THE PROPOSED FINISHED |
| | GRADES, DEPICTING THE PROPOSED LOT DRAINAGE AND, AS |
| | APPLICABLE, FLOOD HAZARD AREAS, FLOODWAYS, AND DESIGN |
| | FLOOD ELEVATIONS; AND IT SHALL BE DRAWN IN ACCORDANCE |
| | WITH AN ACCURATE AND INCLUDED ON A BOUNDARY LINE |
| | SURVEY. (PLEASE PROVIDE CUT SECTIONS FOR ANY PROPOSED |
| | WATER RETAINING SWALES) |
| | |
| | 3) DRAWINGS DO NOT SHOW AS DIGITALLY SIGNED IN ADOBE |
| | READER - SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED |
| | TO BE DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN |
| | ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL |
| | SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A |
| | SPECIFIC TYPE OF E-SIGNATURE). |