| Date |
Text |
| 2023-04-27 11:34:41 | PLAN REVIEW COMMENTS |
| | |
| | PLAN |
| | REVIEW COMMENTS |
| | |
| | 1ST REVIEW: FBC SEVENTH EDITION (2020) |
| | ROBERT MCDOUGAL, CBO |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | (561) 805-6714 |
| | [email protected] |
| | |
| | DENIED BY BUILDING |
| | PLEASE ADDRESS THE ITEMS NOTED BELOW: |
| | |
| | 1) IT APPEARS THAT YOUR CALCULATIONS ON SHEET SP.400 |
| | ARE NOT CORRECT. THE SPA IS 12.5' X 9.0'. THE SURFACE |
| | OF THE POOL WATER IS 112.5 SQUARE FEET IN AREA WHICH IS |
| | LESS THAN 120 SQUARE FEET. THE TOTAL PERIMETER OF THE |
| | POOL IS 34'. THE CONTINOUS 4 FT WIDE DECK CAN BE FIFTY |
| | PERCENT OF 34' OR 17'. THE DRAWINGS APPEAR TO SHOW THAT |
| | HALF OF THE PERIMETER OF THE POOL SPA HAS A CONTINOUS |
| | DECK AT LEAST 4' WIDE. HOWEVER, THERE APPEARS TO BE |
| | SOME OBSTRUCTIONS TO THE POOL ON THE 50 PERCENT THAT |
| | YOU ARE CALLING UNOBSTRUCTED. YOU NEED TO REVISE YOUR |
| | CALCULATIONS AND MAKE SURE THERE ARE NO OBSTRUCTIONS |
| | FOR THE HALF OF THE DECK THAT IS NOT PLANTER. FBC |
| | 454.1.8.5 DECKS. DECKS SHALL HAVE A MINIMUM 4-FOOTWIDE |
| | (1219 MM) UNOBSTRUCTED WIDTH AROUND THE ENTIRE POOL |
| | PERIMETER EXCEPT THAT POOLS OF LESS THAN 120 SQUARE |
| | FEET (11 M2) OF POOL WATER SURFACE AREA SHALL HAVE A |
| | MINIMUM 4-FOOT-WIDE (1219 MM) UNOBSTRUCTED CONTINUOUS |
| | DECK AROUND A MINIMUM OF 50 PERCENT OF THE POOL |
| | PERIMETER. DECKS LESS THAN 4 FEET (1219 MM) WIDE SHALL |
| | HAVE BARRIERS TO PREVENT THEIR USE. DECKS SHALL NOT BE |
| | MORE THAN 10 INCHES (254 MM) BELOW THE TOP OF THE POOL. |
| | FOR POOLS OF 120 SQUARE FEET (11 M2) OR GREATER, 10 |
| | PERCENT OF THE DECK ALONG THE POOL PERIMETER MAY BE |
| | OBSTRUCTED. |
| | |
| | 2) PLEASE SUBMIT A RESPONSE LETTER INDICATING HOW EACH |
| | OF THE REVIEW COMMENTS HAS BEEN ADDRESSED. |
| | |