| Date |
Text |
| 2022-11-30 10:34:04 | 1ST REVIEW FBC-2020 FUEL GAS |
| | PERMIT- 22100175 |
| | 11/30/22 |
| | |
| | CODES IN EFFECT: |
| | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 |
| | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION |
| | 2020 |
| | FS- FLORIDA STATUTES |
| | FAC- FLORIDA ADMINISTRATIVE CODE |
| | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC |
| | |
| | PLAN REVIEW RESULTS: DENIED. THE PERMIT APPLICATION IS |
| | FOR RESIDENTIAL SPA WHICH HAS A GAS-FIRED FIRED POOL |
| | HEATER, HOWEVER SINCE SHEET P.509 & P.700 SHOWS |
| | MULTIPLE POOL HEATERS FOR THE OTHER POOLS AND SPAS THE |
| | APPLICANTS SHOULD CONSIDER SUBMITTING A SEPARATE PERMIT |
| | APPLICATION FOR GAS THAT INCLUDES ALL THE GAS WORK |
| | RELATING TO THE POOLS AND SPAS. IF A SEPARATE PERMIT IS |
| | CHOSEN, I WILL PLACE AN "N" RESULT (NO REVIEW) FOR GAS |
| | AND PERFORM THE REVIEW UNDER THE SEPARATE PERMIT. |
| | PLEASE REVIEW THE COMMENTS AND CONTACT ME IF YOU HAVE |
| | QUESTIONS. |
| | |
| | 1) SHEETS P.700: THE RISER BRANCH THAT CORRELATES TO |
| | KEYNOTE 1 DOES NOT APPEAR TO BE SHOWN ON THE DRAWING. |
| | PLEASE PROVIDE A COMPLETE GAS RISER DRAWING THAT |
| | INCLUDES ALL NEW AND EXISTING GAS PIPING AND |
| | APPLIANCES- SECTIONS 401.3 & 401.4 FBC FG. REFER TO FBC |
| | CHAPTER 4 FUEL FBC- THE RISER SHALL INDICATE: |
| | A) DELIVERY PRESSURE AT THE METER. |
| | B) TOTAL BTU LOAD AND INDIVIDUAL APPLIANCE AND |
| | EQUIPMENT BTU LOADS. |
| | C) TOTAL DEVELOPED LENGTH OF THE SYSTEM FROM THE METER |
| | TO THE MOST REMOTE APPLIANCE OUTLET. |
| | D) BRANCH AND CUT PIPE LENGTH MEASUREMENTS. |
| | E) LOCATIONS OF REGULATORS, SHUTOFF VALVES, AND PIPE |
| | UNIONS. |
| | F) OUTLET PRESSURES AT REGULATORS. |
| | G) LOCATIONS AND TYPES OF PIPE SLEEVES. |
| | H) PIPE SIZING TABLES. |
| | |
| | 2) SP.320, P.509, P.700: SUBMIT MANUFACTURER' S |
| | SPECIFICATIONS FOR THE POOL HEATER- SEC.617.1 FBC FG. |
| | |
| | 3) SP.320, P.509, P.700: INDICATE HOW COMBUSTION AIR |
| | WILL BE PROVIDED TO THE HEATER AND SHOW CALCULATIONS |
| | FOR INDOOR AIR IF APPLICABLE- SEC. 304.1 FBC FG. |
| | |
| | 4) SP.320, P.509, P.700: PROVIDE A VENTING PLAN FOR THE |
| | HEATER- SEC. 503.1 FBC FG. |
| | |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. |
| | |
| | CHRISTOPHER L. COLE |
| | MECHANICAL/PLUMBING PLANS EXAMINER |
| | 401 CLEMATIS STREET |
| | WEST PALM BEACH FL 33401 |
| | 561-805-6719 |
| | CCOLE@WPB |
| | |